Flexential - Philadelphia/Collegeville (PHL01)

Flexential - Philadelphia/Collegeville (PHL01) is an operational data center operated by Flexential in Collegeville, United States. Our footprint estimate of its power is about 13 MW.

Key facts

StatusOperational
OperatorFlexential
Facility power13 MW (range 6.3 MW to 20 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 10,541 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 5,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks
PeeringDB.
Also known asFlexential Philadelphia - Collegeville
Address1000 Black Rock Road
Coordinates40.15170, -75.47953
Websiteflexential.com

Power and grid

Nearest high-voltage substationUpper Providence Substation, 230 kV, 4.2 km away (PECO)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km5
UtilityPeco Energy Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineTexas Eastern Trans Co, interstate pipeline, 1.3 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km10 GW in 60 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity387 g CO₂ per kWh (Pennsylvania, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 58%, nuclear 30.3%, coal 7.1%, wind 1.4%, solar 1.4%. Clean power: 34.3%
Industrial power priceUSD 0.105 per kWh (Pennsylvania, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature11.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.4 °C (2001 to 2025)
Cooling degree days618 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.86 kWh per m² per day
Wind at 50 m4.8 m/s average
Water stress todayLow - Medium (10-20%) (Pennsylvania)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Flexential - Philadelphia/Collegeville (PHL01) use?

We estimate the facility power at about 13 MW. Estimate from building footprint, low confidence.

How close is Flexential - Philadelphia/Collegeville (PHL01) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Upper Providence Substation (230 kV), about 4.2 km away. The local utility is Peco Energy Co, in the PJM balancing area.

How clean is the power for Flexential - Philadelphia/Collegeville (PHL01)?

The grid in Pennsylvania emits about 387 g CO₂ per kWh (2025). Largest sources: gas 58%, nuclear 30.3%, coal 7.1%.

Who operates Flexential - Philadelphia/Collegeville (PHL01)?

Flexential.

Data centers near Collegeville

More Flexential data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.