Rackspace Dallas Grapevine (DFW1)
Rackspace Dallas Grapevine (DFW1) is an operational data center operated by Rackspace, US in Grapevine, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Rackspace, US |
| Address | 801 Industrial Blvd. |
| Coordinates | 32.92919, -97.10485 |
| Website | rackspace.com |
Power and grid
| Nearest high-voltage substation | Grapevine Ball Street, 138 kV, 1.9 km away (Oncor) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 345 kV, 10.8 km away |
| HV substations within 10 km | 22 |
| Utility | Denton County Elec Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | Energy Transfer, intrastate pipeline, 5.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.4 GW in 16 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 1,559 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Rackspace Dallas Grapevine (DFW1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Grapevine Ball Street (138 kV), about 1.9 km away. The local utility is Denton County Elec Coop, INC, in the ERCO balancing area.
How clean is the power for Rackspace Dallas Grapevine (DFW1)?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Rackspace Dallas Grapevine (DFW1)?
Rackspace, US.
Data centers near Grapevine
- Verizon Wireless Mew Building 6.8 km · 38 MW
- Amazon Web Services 9.3 km · 5 MW
- QTS Irving - Dallas (DFW1) 11.9 km · 48 MW
- Data center in Coppell 12.1 km · 24 MW
- Centersquare Dallas (DFW1) 12.3 km · 51 MW
- CyrusOne Dallas (Lewisville) 12.8 km
- TierPoint Dallas Forth Worth 14.9 km
- Facebook Fort Worth Datacenter 15.3 km · 88 MW
Sources