QTS Irving - Dallas (DFW1)
QTS Irving - Dallas (DFW1) is an operational data center operated by QTS Realty Trust in Irving, United States. Our footprint estimate of its power is about 48 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | QTS Realty Trust |
| Facility power | 48 MW (range 24 MW to 77 MW) Estimate from building footprint, low confidence. Footprint estimate: about 39,894 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 21,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 17 networks, 3 internet exchanges PeeringDB. |
| Also known as | QTS Irving - Dallas Data Center Campus |
| Address | 6431 Longhorn Drive |
| Coordinates | 32.89709, -96.98299 |
| Website | qtsdatacenters.com/data-centers/irving |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 900 m away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 345 kV, 1.5 km away |
| HV substations within 10 km | 37 |
| Utility | Hilco Electric Cooperative, INC. (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | ERCO |
| Nearest gas pipeline | Atmos Pipeline - Texas, intrastate pipeline, 3.1 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.4 GW in 15 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 1,559 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does QTS Irving - Dallas (DFW1) use?
We estimate the facility power at about 48 MW. Estimate from building footprint, low confidence.
How close is QTS Irving - Dallas (DFW1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 900 m away. The local utility is Hilco Electric Cooperative, INC., in the ERCO balancing area.
How clean is the power for QTS Irving - Dallas (DFW1)?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates QTS Irving - Dallas (DFW1)?
QTS Realty Trust.
Data centers near Irving
- Data center in Coppell 277 m · 24 MW
- Centersquare Dallas (DFW1) 9.0 km · 51 MW
- Amazon Web Services 9.7 km · 5 MW
- Centersquare Dallas (DFW3) 10.4 km
- CyrusOne Dallas (Carrollton) 11.6 km
- Prime DFW01-01 11.7 km · 6.7 MW
- CyrusOne Dallas (Lewisville) 11.7 km
- Evocative DA4 11.8 km · 9.9 MW
More QTS Realty Trust data centers
- QTS Atlanta-Metro (ATL1) United States
- QTS Atlanta-Suwanee (SUW1) United States
- QTS Chicago (CHI1) United States
- QTS Atlanta-Fayetteville (ATL2) United States
- QTS Eemshaven (EEM1) Netherlands
- QTS Sacramento (SAC1) United States
- QTS Ashburn (ASH1) United States
- QTS Santa Clara (SJC1/SJC2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.