Evocative DA4
Evocative DA4 is an operational data center operated by VPLS in Dallas, United States. Our footprint estimate of its power is about 9.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | VPLS |
| Facility power | 9.9 MW (range 5 MW to 16 MW) Estimate from building footprint, low confidence. Footprint estimate: about 8,258 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 42 networks, 4 internet exchanges PeeringDB. |
| Also known as | Prime DFW01-01 |
| Address | 1515 Round Table Dr |
| Coordinates | 32.83797, -96.87831 |
| Website | evocative.com |
Power and grid
| Utility | Hilco Electric Cooperative, INC. (cooperative) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Atmos Pipeline - Texas, intrastate pipeline, 10.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 45.3 °C (2001 to 2025) |
| Cooling degree days | 1,559 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Evocative DA4 use?
We estimate the facility power at about 9.9 MW. Estimate from building footprint, low confidence.
How clean is the power for Evocative DA4?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Evocative DA4?
VPLS.
Data centers near Dallas
- Prime DFW01-01 145 m · 6.7 MW
- DataBank Dallas (DFW6) 1.2 km
- Lumen Dallas 6 1.2 km · 2.2 MW
- 3HCloud - DFW-1 1.2 km
- DataBank Dallas (DFW4) 1.9 km · 11 MW
- CoreSpace Dallas 2.3 km · 6.8 MW
- Level(3) Dallas 3.5 km · 7 MW
- Colo4Dallas 3.9 km · 8.3 MW
More VPLS data centers
- Evocative EWR1 United States
- Evocative SJC11 United States
- Evocative Virginia (VA1) United States
- Evocative SJC3 United States
- Evocative BOS1 United States
- Evocative DAL6 United States
- Evocative Emeryville (EM1) United States
- Evocative LAX14 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.