Evocative EWR1
Evocative EWR1 is an operational data center operated by VPLS in Secaucus, United States. Our footprint estimate of its power is about 17 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | VPLS |
| Facility power | 17 MW (range 8.5 MW to 27 MW) Estimate from building footprint, low confidence. Footprint estimate: about 14,248 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 7,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 17 networks, 1 internet exchanges PeeringDB. |
| Also known as | Evocative Secaucus |
| Address | 1 Enterprise Ave N |
| Coordinates | 40.78766, -74.06802 |
| Website | evocative.com |
Power and grid
| Utility | Public Service Elec & Gas Co (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | PJM |
| Nearest gas pipeline | Transcontinental Gas PL, interstate pipeline, 1.5 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 265 g CO₂ per kWh (New Jersey, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.8%, nuclear 43.2%, solar 9%, oil and other fossil 1.5%, bioenergy 0.9%. Clean power: 52.8% |
| Industrial power price | USD 0.162 per kWh (New Jersey, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.7 °C (2001 to 2025) |
| Cooling degree days | 504 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.87 kWh per m² per day |
| Wind at 50 m | 5.3 m/s average |
| Water stress today | Medium - High (20-40%) (New Jersey) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Evocative EWR1 use?
We estimate the facility power at about 17 MW. Estimate from building footprint, low confidence.
How clean is the power for Evocative EWR1?
The grid in New Jersey emits about 265 g CO₂ per kWh (2025). Largest sources: gas 45.8%, nuclear 43.2%, solar 9%.
Who operates Evocative EWR1?
VPLS.
Data centers near Secaucus
- Centersquare New Jersey (EWR5) 191 m · 21 MW
- CoreSite - Secaucus (NY2) 428 m · 5.8 MW
- InterServer Teb2 515 m
- H5 Secaucus 641 m
- H5 Data Centers Secaucus (NJ01) 763 m
- Equinix NY2/NY4/NY5/NY6 - New York, Secaucus 1.1 km · 29 MW
- NJDC2 - 300 J F Kennedy Blvd 1.3 km · 64 MW
- Equinix NY3 - New York, Secaucus 1.4 km · 9.2 MW
More VPLS data centers
- Evocative DA4 United States
- Evocative SJC11 United States
- Evocative Virginia (VA1) United States
- Evocative SJC3 United States
- Evocative BOS1 United States
- Evocative DAL6 United States
- Evocative Emeryville (EM1) United States
- Evocative LAX14 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.