QTS Sacramento (SAC1)
QTS Sacramento (SAC1) is an operational data center operated by QTS Realty Trust in Sacramento, United States. Our footprint estimate of its power is about 8.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | QTS Realty Trust |
| Facility power | 8.6 MW (range 4.3 MW to 14 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,145 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 13 networks, 1 internet exchanges PeeringDB. |
| Also known as | QTS Sacramento |
| Address | 1100 North Market Blvd |
| Coordinates | 38.64641, -121.48633 |
| Website | qtsdatacenters.com/data-centers/sacramento |
Power and grid
| Nearest high-voltage substation | Natomas Substation, 230 kV, 400 m away (Sacramento Municipal Utility District) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 9 |
| Utility | Sacramento Municipal Util Dist (political subdivision) Electric retail service territory (HIFLD, US government). |
| Balancing authority | BANC |
| Nearest gas pipeline | California Gas Transmission Co, intrastate pipeline, 900 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 2.7 GW in 64 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 16.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 46.7 °C (2001 to 2025) |
| Cooling degree days | 942 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.23 kWh per m² per day |
| Wind at 50 m | 4.3 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does QTS Sacramento (SAC1) use?
We estimate the facility power at about 8.6 MW. Estimate from building footprint, low confidence.
How close is QTS Sacramento (SAC1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Natomas Substation (230 kV), about 400 m away. The local utility is Sacramento Municipal Util Dist, in the BANC balancing area.
How clean is the power for QTS Sacramento (SAC1)?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates QTS Sacramento (SAC1)?
QTS Realty Trust.
Data centers near Sacramento
- RagingWire CA1 - NTT 500 m · 16 MW
- RagingWire CA2 - NTT 656 m · 18 MW
- RagingWire CA3 - NTT 1.1 km · 13 MW
- EdgeConneX Sacramento (EDCSAC01) 19.1 km · 3.7 MW
- Sungard AS Sacramento 19.4 km
- Quest Roseville 21.9 km
More QTS Realty Trust data centers
- QTS Atlanta-Metro (ATL1) United States
- QTS Atlanta-Suwanee (SUW1) United States
- QTS Irving - Dallas (DFW1) United States
- QTS Chicago (CHI1) United States
- QTS Atlanta-Fayetteville (ATL2) United States
- QTS Eemshaven (EEM1) Netherlands
- QTS Ashburn (ASH1) United States
- QTS Santa Clara (SJC1/SJC2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.