RagingWire CA3 - NTT

RagingWire CA3 - NTT is an operational data center operated by RagingWire Data Centers - NTT in Sacramento, United States. Our footprint estimate of its power is about 13 MW.

Key facts

StatusOperational
OperatorRagingWire Data Centers - NTT
Facility power13 MW (range 6.4 MW to 21 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 10,690 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 5,600 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks5 networks
PeeringDB.
Also known asRagingWire CA3
Address1625 W National Dr
Coordinates38.64438, -121.49864
Websiteragingwire.com

Power and grid

Nearest high-voltage substationNatomas Substation, 230 kV, 1.3 km away (Sacramento Municipal Utility District)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km8
UtilitySacramento Municipal Util Dist (political subdivision)
Electric retail service territory (HIFLD, US government).
Balancing authorityBANC
Nearest gas pipelineCalifornia Gas Transmission Co, intrastate pipeline, 1 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km2.7 GW in 64 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature16.6 °C
NASA POWER, average of 2001 to 2025.
Highest temperature46.7 °C (2001 to 2025)
Cooling degree days942 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.23 kWh per m² per day
Wind at 50 m4.3 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does RagingWire CA3 - NTT use?

We estimate the facility power at about 13 MW. Estimate from building footprint, low confidence.

How close is RagingWire CA3 - NTT to the power grid?

The nearest high-voltage substation in OpenStreetMap is Natomas Substation (230 kV), about 1.3 km away. The local utility is Sacramento Municipal Util Dist, in the BANC balancing area.

How clean is the power for RagingWire CA3 - NTT?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates RagingWire CA3 - NTT?

RagingWire Data Centers - NTT.