Data Center Directory

RagingWire TX1 - NTT

RagingWire TX1 - NTT is an operational data center operated by RagingWire Data Centers - NTT in Garland, United States. Our footprint estimate of its power is about 17 MW.

Key facts

StatusOperational
OperatorRagingWire Data Centers - NTT
Facility power17 MW (range 8.6 MW to 27 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 14,278 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,300 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks7 networks, 1 internet exchanges
PeeringDB.
Also known asNTT
Address2008 Lookout Dr
Coordinates32.98107, -96.65780
Websiteragingwire.com

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 300 m away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationBen Davis Substation, 345 kV, 5 km away
HV substations within 10 km38
UtilityCity Of Garland (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityERCO
Nearest gas pipelineEnergy Transfer, intrastate pipeline, 19 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.9 GW in 20 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity379 g CO₂ per kWh (Texas, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8%
Industrial power priceUSD 0.072 per kWh (Texas, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature18.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature44.7 °C (2001 to 2025)
Cooling degree days1,494 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.64 kWh per m² per day
Wind at 50 m6.5 m/s average
Water stress todayHigh (40-80%) (Texas)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050High (40-80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does RagingWire TX1 - NTT use?

We estimate the facility power at about 17 MW. Estimate from building footprint, low confidence.

How close is RagingWire TX1 - NTT to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 300 m away. The local utility is City Of Garland, in the ERCO balancing area.

How clean is the power for RagingWire TX1 - NTT?

The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.

Who operates RagingWire TX1 - NTT?

RagingWire Data Centers - NTT.

Data centers near Garland

More RagingWire Data Centers - NTT data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.