Digital Realty
Digital Realty is an operational data center operated by Digital Realty in Sachse, United States. Our footprint estimate of its power is about 23 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 23 MW (range 11 MW to 36 MW) Estimate from building footprint, low confidence. Footprint estimate: about 18,878 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 9,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Ferris Road 1505 |
| Coordinates | 32.97443, -96.65016 |
Power and grid
| Utility | City Of Garland (municipal) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Energy Transfer, intrastate pipeline, 19.6 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.7 °C (2001 to 2025) |
| Cooling degree days | 1,494 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty use?
We estimate the facility power at about 23 MW. Estimate from building footprint, low confidence.
How clean is the power for Digital Realty?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Digital Realty?
Digital Realty.
Data centers near Sachse
- NTT 936 m · 20 MW
- RagingWire TX1 - NTT 1.0 km · 17 MW
- NTT 1.1 km · 17 MW
- Stream Data Centers - DFW VII 1.1 km · 27 MW
- Stream DFW IV 3.1 km · 1.7 MW
- Aligned Data Centers DFW-04 3.6 km · 18 MW
- Flexential - Dallas/Plano (DFW01) 4.0 km · 27 MW
- Aligned DFW-02 4.5 km · 7.6 MW
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.