Aligned DFW-02
Aligned DFW-02 is an operational data center operated by Aligned in Plano, United States. Our footprint estimate of its power is about 7.6 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Aligned |
| Facility power | 7.6 MW (range 3.8 MW to 12 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,328 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Summit Avenue 2800, 75074, Plano |
| Coordinates | 33.00900, -96.67514 |
| Website | aligneddc.com/dallas-data-centers |
Power and grid
| Utility | Grayson-Collin Elec Coop, INC (cooperative) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | ERCO |
| Nearest gas pipeline | Energy Transfer, intrastate pipeline, 16.1 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 379 g CO₂ per kWh (Texas, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 48.3%, wind 21.7%, coal 11.6%, solar 10.7%, nuclear 7%. Clean power: 39.8% |
| Industrial power price | USD 0.072 per kWh (Texas, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 18.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 44.7 °C (2001 to 2025) |
| Cooling degree days | 1,494 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.64 kWh per m² per day |
| Wind at 50 m | 6.5 m/s average |
| Water stress today | High (40-80%) (Texas) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Aligned DFW-02 use?
We estimate the facility power at about 7.6 MW. Estimate from building footprint, low confidence.
How clean is the power for Aligned DFW-02?
The grid in Texas emits about 379 g CO₂ per kWh (2025). Largest sources: gas 48.3%, wind 21.7%, coal 11.6%.
Who operates Aligned DFW-02?
Aligned.
Data centers near Plano
- Aligned Dallas (DFW-01) 125 m · 5.2 MW
- GIP Plano 825 m
- Flexential - Dallas/Plano (DFW01) 841 m · 27 MW
- Stream DFW IV 1.6 km · 1.7 MW
- Aligned Data Centers DFW-04 1.7 km · 18 MW
- Stream Data Centers - DFW VII 3.3 km · 27 MW
- NTT 3.4 km · 17 MW
- RagingWire TX1 - NTT 3.5 km · 17 MW
More Aligned data centers
- Aligned IAD-03 United States
- Aligned IAD-01 United States
- Aligned Data Center - Chicago ORD-01 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.