Aligned Data Center - Chicago ORD-01

Aligned Data Center - Chicago ORD-01 is an operational data center operated by Aligned in Northlake, United States. Our footprint estimate of its power is about 18 MW.

Key facts

StatusOperational
OperatorAligned
Facility power18 MW (range 8.8 MW to 28 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 14,712 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 7,700 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asAligned Data Center - Chicago ORD-02
AddressNorth Northwest Avenue 505, 60164, Northlake
Coordinates41.91400, -87.91752

Power and grid

Nearest high-voltage substationNorthlake Substation, 138 kV, 900 m away (Commonwealth Edison)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationComEd Elmhurst 138kV-345kV Substation, 345 kV, 1.1 km away
HV substations within 10 km15
UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNorthern Illinois Gas Co, intrastate pipeline, 800 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.9 GW in 33 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.5 °C (2001 to 2025)
Cooling degree days465 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Aligned Data Center - Chicago ORD-01 use?

We estimate the facility power at about 18 MW. Estimate from building footprint, low confidence.

How close is Aligned Data Center - Chicago ORD-01 to the power grid?

The nearest high-voltage substation in OpenStreetMap is Northlake Substation (138 kV), about 900 m away. The local utility is Commonwealth Edison Co, in the PJM balancing area.

How clean is the power for Aligned Data Center - Chicago ORD-01?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates Aligned Data Center - Chicago ORD-01?

Aligned.