Aligned Chicago (ORD-01)
Aligned Chicago (ORD-01) is an operational data center operated by Aligned Data Centers in Northlake, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Aligned Data Centers |
| Also known as | Aligned Chicago (ORD-02) |
| Address | 505 Northwest Ave |
| Coordinates | 41.91346, -87.91876 |
| Website | aligneddc.com/chicago |
Power and grid
| Nearest high-voltage substation | Northlake Substation, 138 kV, 1 km away (Commonwealth Edison) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | ComEd Elmhurst 138kV-345kV Substation, 345 kV, 1.1 km away |
| HV substations within 10 km | 15 |
| Utility | Commonwealth Edison Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Northern Illinois Gas Co, intrastate pipeline, 700 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 3.9 GW in 33 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 247 g CO₂ per kWh (Illinois, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3% |
| Industrial power price | USD 0.113 per kWh (Illinois, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.5 °C (2001 to 2025) |
| Cooling degree days | 465 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Medium - High (20-40%) (Illinois) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Aligned Chicago (ORD-01) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Northlake Substation (138 kV), about 1 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.
How clean is the power for Aligned Chicago (ORD-01)?
The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.
Who operates Aligned Chicago (ORD-01)?
Aligned Data Centers.
Data centers near Northlake
- Aligned Data Center - Chicago ORD-01 119 m · 18 MW
- Ascent - CH2 911 m
- Microsoft - Azure Datacenter 1.1 km · 28 MW
- Data center in Northlake 2.3 km · 6.4 MW
- Digital Realty CHI (9333 Grand Ave) 5.2 km
- Digital Realty CHI (9377 Grand Ave) 5.2 km · 26 MW
- TierPoint Chicago - West 5.2 km
- CDC4 - 1808 Swift Dr 6.6 km
More Aligned Data Centers data centers
- Aligned Ashburn (IAD-02) United States
- Aligned Data Centers United States
- Aligned Phoenix (PHX-01) United States
- Aligned Data Centers DFW-04 United States
- Alinged Data Center DFW-03 United States
- Aligned DC - PDX-01 United States
- Aligned Data Centers United States
- Aligned Dallas (DFW-01) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.