Aligned Phoenix (PHX-01)
Aligned Phoenix (PHX-01) is an operational data center operated by Aligned Data Centers in Phoenix, United States. Our footprint estimate of its power is about 26 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Aligned Data Centers |
| Facility power | 26 MW (range 11 MW to 66 MW) Estimate from building footprint, low confidence. Footprint estimate: about 219,124 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 11,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 6 networks, 1 internet exchanges PeeringDB. |
| Also known as | Aligned Energy Data Center |
| Address | 2500 W Union Hills Drive, Phoenix |
| Opened | 2017 |
| Coordinates | 33.65888, -112.11061 |
| Website | aligneddc.com/phoenix |
Power and grid
| Utility | City Of Mesa (municipal) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | WALC |
| Nearest gas pipeline | El Paso Natural Gas Co, interstate pipeline, 5.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 311 g CO₂ per kWh (Arizona, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 43%, nuclear 25.6%, solar 17.5%, coal 7.5%, hydro 4.1%. Clean power: 49.8% |
| Industrial power price | USD 0.097 per kWh (Arizona, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 22.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 48.6 °C (2001 to 2025) |
| Cooling degree days | 2,283 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.8 kWh per m² per day |
| Wind at 50 m | 4.4 m/s average |
| Water stress today | Extremely High (>80%) (Arizona) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Aligned Phoenix (PHX-01) use?
We estimate the facility power at about 26 MW. Estimate from building footprint, low confidence.
How clean is the power for Aligned Phoenix (PHX-01)?
The grid in Arizona emits about 311 g CO₂ per kWh (2025). Largest sources: gas 43%, nuclear 25.6%, solar 17.5%.
Who operates Aligned Phoenix (PHX-01)?
Aligned Data Centers.
Data centers near Phoenix
- Accelera Data Systems 660 m
- Flexential - Phoenix (PHX01) 3.1 km · 19 MW
- Sungard AS Scottsdale 18.1 km
- Lumen Technologies data center in Phoenix 18.8 km · 3.4 MW
- DataPro USA Web Development 18.9 km
- VaultLogix 19.7 km
- DataBank Phoenix (PHX1) 19.7 km
- Iron Mountain Data Center - Scottsdale (AZS-1) 20.0 km
More Aligned Data Centers data centers
- Aligned Ashburn (IAD-02) United States
- Aligned Data Centers United States
- Aligned Data Centers DFW-04 United States
- Alinged Data Center DFW-03 United States
- Aligned DC - PDX-01 United States
- Aligned Data Centers United States
- Aligned Dallas (DFW-01) United States
- Aligned Ashburn (IAD-01) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.