QTS Chicago (CHI1)
QTS Chicago (CHI1) is an operational data center operated by QTS Realty Trust in Chicago, United States. Our footprint estimate of its power is about 40 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | QTS Realty Trust |
| Facility power | 40 MW (range 20 MW to 63 MW) Estimate from building footprint, low confidence. Footprint estimate: about 32,991 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 17,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 14 networks, 4 internet exchanges PeeringDB. |
| Also known as | QTS Chicago |
| Address | 2800 S. Ashland Ave |
| Coordinates | 41.84190, -87.66831 |
| Website | qtsdatacenters.com/data-centers/chicago |
Power and grid
| Utility | Commonwealth Edison Co (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | PJM |
| Nearest gas pipeline | Natural Gas PL Co of Am, interstate pipeline, 5.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 247 g CO₂ per kWh (Illinois, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3% |
| Industrial power price | USD 0.113 per kWh (Illinois, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.7 °C (2001 to 2025) |
| Cooling degree days | 362 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 7.3 m/s average |
| Water stress today | Medium - High (20-40%) (Illinois) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does QTS Chicago (CHI1) use?
We estimate the facility power at about 40 MW. Estimate from building footprint, low confidence.
How clean is the power for QTS Chicago (CHI1)?
The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.
Who operates QTS Chicago (CHI1)?
QTS Realty Trust.
Data centers near Chicago
- Iron Mountain Data & Record Storage 2.0 km · 14 MW
- CoreSite - Chicago (CH2) 3.2 km · 5.4 MW
- TierPoint Chicago - Polk 3.9 km
- Serverfarm CH1 Chicago 4.0 km · 29 MW
- Equinix CH1/CH2/CH4 - Chicago 4.3 km · 78 MW
- Netrality Chicago - 717 S Wells 4.5 km
- Printer's Square Chicago (600 S Federal) 4.8 km · 0.9 MW
- 365 Data Centers Chicago (CH6) 4.9 km
More QTS Realty Trust data centers
- QTS Atlanta-Metro (ATL1) United States
- QTS Atlanta-Suwanee (SUW1) United States
- QTS Irving - Dallas (DFW1) United States
- QTS Atlanta-Fayetteville (ATL2) United States
- QTS Eemshaven (EEM1) Netherlands
- QTS Sacramento (SAC1) United States
- QTS Ashburn (ASH1) United States
- QTS Santa Clara (SJC1/SJC2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.