QTS Chicago (CHI1)

QTS Chicago (CHI1) is an operational data center operated by QTS Realty Trust in Chicago, United States. Our footprint estimate of its power is about 40 MW.

Key facts

StatusOperational
OperatorQTS Realty Trust
Facility power40 MW (range 20 MW to 63 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 32,991 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 17,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks14 networks, 4 internet exchanges
PeeringDB.
Also known asQTS Chicago
Address2800 S. Ashland Ave
Coordinates41.84190, -87.66831
Websiteqtsdatacenters.com/data-centers/chicago

Power and grid

UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNatural Gas PL Co of Am, interstate pipeline, 5.8 km away
US Energy Information Administration pipeline map. Straight-line distance.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34.7 °C (2001 to 2025)
Cooling degree days362 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m7.3 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does QTS Chicago (CHI1) use?

We estimate the facility power at about 40 MW. Estimate from building footprint, low confidence.

How clean is the power for QTS Chicago (CHI1)?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates QTS Chicago (CHI1)?

QTS Realty Trust.