Serverfarm CH1 Chicago

Serverfarm CH1 Chicago is an operational data center operated by Serverfarm in Chicago, United States. Our footprint estimate of its power is about 29 MW.

Key facts

StatusOperational
OperatorServerfarm
Facility power29 MW (range 15 MW to 47 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,093 m² building outline x 6 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 12,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks5 networks, 2 internet exchanges
PeeringDB.
Also known asDataBank Chicago (ORD2) · Serverfarm CH1
Address840 S. Canal Street
Coordinates41.87091, -87.64015
Websiteserverfarmllc.com/data-centers/chicago-data-center

Power and grid

UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNatural Gas PL Co of Am, interstate pipeline, 8.4 km away
US Energy Information Administration pipeline map. Straight-line distance.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34.7 °C (2001 to 2025)
Cooling degree days362 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m7.3 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Serverfarm CH1 Chicago use?

We estimate the facility power at about 29 MW. Estimate from building footprint, low confidence.

How clean is the power for Serverfarm CH1 Chicago?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates Serverfarm CH1 Chicago?

Serverfarm.