Serverfarm LAX1 Los Angeles
Serverfarm LAX1 Los Angeles is an operational data center operated by Serverfarm in El Segundo, United States. Our footprint estimate of its power is about 11 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Serverfarm |
| Facility power | 11 MW (range 5.5 MW to 18 MW) Estimate from building footprint, low confidence. Footprint estimate: about 9,247 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 4,700 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 3 networks PeeringDB. |
| Also known as | Serverfarm - LAX1 |
| Address | 444 North Nash Street |
| Opened | 1973 |
| Coordinates | 33.92161, -118.38655 |
| Website | serverfarmllc.com/los-angeles-data-center |
Power and grid
| Nearest high-voltage substation | Chevmain Substation, 220 kV, 2.3 km away (Southern California Edison) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 13 |
| Utility | Southern California Edison Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | Southern California Gas Co, intrastate pipeline, 300 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 11 GW in 84 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 17.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.5 °C (2001 to 2025) |
| Cooling degree days | 530 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.65 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Serverfarm LAX1 Los Angeles use?
We estimate the facility power at about 11 MW. Estimate from building footprint, low confidence.
How close is Serverfarm LAX1 Los Angeles to the power grid?
The nearest high-voltage substation in OpenStreetMap is Chevmain Substation (220 kV), about 2.3 km away. The local utility is Southern California Edison Co, in the CISO balancing area.
How clean is the power for Serverfarm LAX1 Los Angeles?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates Serverfarm LAX1 Los Angeles?
Serverfarm.
Data centers near El Segundo
- Equinix LA3/LA4 - Los Angeles, El Segundo 259 m
- Centurylink data center in El Segundo 433 m · 6.9 MW
- Digital Realty LAX (2260 E El Segundo) 683 m · 10 MW
- QuadraNet LAX 2.8 km
- Evocative LAX14 4.0 km
- Centersquare Los Angeles (LAX4) 6.1 km
- Equinix LA7 - Los Angeles 11.0 km · 9 MW
- Fireline Data Center 15.8 km
More Serverfarm data centers
- Serverfarm CH1 Chicago United States
- Serverfarm LON1 – London Data Center United Kingdom
- ServerFarm SC1 United States
- Serverfarm AMS1 Amsterdam Netherlands
- Serverfarm ATL1 Atlanta United States
- Serverfarm CH2 Oak Brook / Chicago United States
- Serverfarm TiTAN Moses Lake United States
- Serverfarm TOR1 Toronto Canada
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.