QuadraNet LAX
QuadraNet LAX is an operational data center operated by QuadraNet Enterprises in Los Angeles, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | QuadraNet Enterprises |
| Networks | 6 networks PeeringDB. |
| Address | 6171 W Century Blvd, Basement |
| Coordinates | 33.94589, -118.39355 |
| Website | quadranet.com |
Power and grid
| Nearest high-voltage substation | Receiving Station N - Airport, 138 kV, 2.4 km away (Los Angeles Department of Water and Power) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Scattergood Substation, 230 kV, 4.2 km away |
| HV substations within 10 km | 12 |
| Utility | Los Angeles Department Of Water & Power (municipal) Electric retail service territory (HIFLD, US government). |
| Balancing authority | LDWP |
| Nearest gas pipeline | Southern California Gas Co, intrastate pipeline, 300 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 11 GW in 84 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 17.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.5 °C (2001 to 2025) |
| Cooling degree days | 530 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.65 kWh per m² per day |
| Wind at 50 m | 4 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is QuadraNet LAX to the power grid?
The nearest high-voltage substation in OpenStreetMap is Receiving Station N - Airport (138 kV), about 2.4 km away. The local utility is Los Angeles Department Of Water & Power, in the LDWP balancing area.
How clean is the power for QuadraNet LAX?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates QuadraNet LAX?
QuadraNet Enterprises.
Data centers near Los Angeles
- Serverfarm LAX1 Los Angeles 2.8 km · 11 MW
- Equinix LA3/LA4 - Los Angeles, El Segundo 2.9 km
- Centurylink data center in El Segundo 3.2 km · 6.9 MW
- Digital Realty LAX (2260 E El Segundo) 3.5 km · 10 MW
- Evocative LAX14 6.7 km
- Centersquare Los Angeles (LAX4) 7.1 km
- Fireline Data Center 13.3 km
- Equinix LA7 - Los Angeles 13.4 km · 9 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.