Equinix LA7 - Los Angeles

Equinix LA7 - Los Angeles is an operational data center operated by Equinix in Los Angeles, United States. Our footprint estimate of its power is about 9 MW.

Key facts

StatusOperational
OperatorEquinix
Facility power9 MW (range 4.5 MW to 14 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 7,541 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,800 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks2 networks, 1 internet exchanges
PeeringDB.
Also known asEquinix
Address1501 Francisco Street, Torrance
Coordinates33.85086, -118.30400
Websiteequinix.com/locations/americas-colocation/united-states-colocation/los-angeles-data-centers/la7

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 400 m away (Los Angeles Department of Water and Power)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationLa Fresa Substation, 220 kV, 3.3 km away
HV substations within 10 km11
UtilityLos Angeles Department Of Water & Power (municipal)
Electric retail service territory (HIFLD, US government).
Balancing authorityLDWP
Nearest gas pipelineSouthern California Gas Co, intrastate pipeline, 400 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km11 GW in 87 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature17.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature39.5 °C (2001 to 2025)
Cooling degree days530 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.65 kWh per m² per day
Wind at 50 m4 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Equinix LA7 - Los Angeles use?

We estimate the facility power at about 9 MW. Estimate from building footprint, low confidence.

How close is Equinix LA7 - Los Angeles to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 400 m away. The local utility is Los Angeles Department Of Water & Power, in the LDWP balancing area.

How clean is the power for Equinix LA7 - Los Angeles?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates Equinix LA7 - Los Angeles?

Equinix.