Printer's Square Chicago (600 S Federal)
Printer's Square Chicago (600 S Federal) is an operational data center operated by Printer's Square in Chicago, United States. Our footprint estimate of its power is about 0.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Printer's Square |
| Facility power | 0.9 MW (range 0.4 MW to 1.4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 726 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 380 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 7 networks, 3 internet exchanges PeeringDB. |
| Also known as | Digital Realty CHI (600-780 S Federal) · DataBank Chicago (ORD1) · CDC2 - 600 S Federal st · Digital Realty ORD11 |
| Address | 600 S Federal |
| Coordinates | 41.87430, -87.62993 |
| Website | printerssquare.com |
Power and grid
| Nearest high-voltage substation | LaSalle Substation, 138 kV, 200 m away (Commonwealth Edison) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | ComEd Taylor 138kV-345kV Substation, 345 kV, 700 m away |
| HV substations within 10 km | 31 |
| Utility | Commonwealth Edison Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Natural Gas PL Co of Am, interstate pipeline, 9.3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.5 GW in 33 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 247 g CO₂ per kWh (Illinois, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3% |
| Industrial power price | USD 0.113 per kWh (Illinois, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 9.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.7 °C (2001 to 2025) |
| Cooling degree days | 362 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.67 kWh per m² per day |
| Wind at 50 m | 7.3 m/s average |
| Water stress today | Medium - High (20-40%) (Illinois) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Printer's Square Chicago (600 S Federal) use?
We estimate the facility power at about 0.9 MW. Estimate from building footprint, low confidence.
How close is Printer's Square Chicago (600 S Federal) to the power grid?
The nearest high-voltage substation in OpenStreetMap is LaSalle Substation (138 kV), about 200 m away. The local utility is Commonwealth Edison Co, in the PJM balancing area.
How clean is the power for Printer's Square Chicago (600 S Federal)?
The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.
Who operates Printer's Square Chicago (600 S Federal)?
Printer's Square.
Data centers near Chicago
- 365 Data Centers Chicago (CH6) 247 m
- Netrality Chicago - 717 S Wells 317 m
- Cogent Chicago 1 599 m
- West Monroe 853 m
- Hut 8 H100 Cluster 874 m · 1.4 MW
- Serverfarm CH1 Chicago 927 m · 29 MW
- Level(3) Chicago (Canal) 1.1 km
- TierPoint Chicago - Polk 1.1 km