Hut 8 H100 Cluster

Hut 8 H100 Cluster is an operational AI data center operated by Hut 8 in Chicago Loop, United States. Its power is about 1.4 MW. Epoch AI estimates about 1,000 H100-equivalent AI chips (NVIDIA H100 SXM5 80GB).

Key facts

StatusOperational
OperatorHut 8
Facility power1.4 MW
Reported (Epoch AI or owner data)
AI compute1,000 H100-equivalents
AI chipsNVIDIA H100 SXM5 80GB
Reported (Epoch AI or owner data)
Chip count1,000
Largest reported cluster at this site (Epoch AI).
GPU capacity if all AIabout 610 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressChicago, USA
Coordinates41.88195, -87.63236

Power and grid

Nearest high-voltage substationLaSalle Substation, 138 kV, 1 km away (Commonwealth Edison)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationComEd Taylor 138kV-345kV Substation, 345 kV, 1.3 km away
HV substations within 10 km31
UtilityCommonwealth Edison Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityPJM
Nearest gas pipelineNatural Gas PL Co of Am, interstate pipeline, 9.4 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km3.8 GW in 31 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature9.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34.7 °C (2001 to 2025)
Cooling degree days362 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.67 kWh per m² per day
Wind at 50 m7.3 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

GPU clusters at this site

ClusterChipsCountPowerSince
Hut 8 H100 ClusterNVIDIA H100 SXM5 80GB1,0001.4 MW2024-09-26

Source: Epoch AI GPU Clusters.

Satellite view

Questions

How much power does Hut 8 H100 Cluster use?

Public data puts the facility power at about 1.4 MW. Reported (Epoch AI or owner data).

What chips does Hut 8 H100 Cluster use?

Reported chips: NVIDIA H100 SXM5 80GB.

How close is Hut 8 H100 Cluster to the power grid?

The nearest high-voltage substation in OpenStreetMap is LaSalle Substation (138 kV), about 1 km away. The local utility is Commonwealth Edison Co, in the PJM balancing area.

How clean is the power for Hut 8 H100 Cluster?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates Hut 8 H100 Cluster?

Hut 8.

Data centers near Chicago Loop

More Hut 8 data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.