SAP Building 13
SAP Building 13 is an operational data center in St. Leon-Rot, Germany. Our footprint estimate of its power is about 19 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 19 MW (range 9.6 MW to 31 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,021 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 8,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | SAP-Allee 19, 68789, St. Leon-Rot |
| Coordinates | 49.24051, 8.64362 |
Power and grid
| Nearest high-voltage substation | 110kV-Umspannwerk Östringen, 110 kV, 4.8 km away (Netze BW) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Wiesloch, 380 kV, 6 km away |
| HV substations within 10 km | 4 |
| Power plants within 50 km | 6.6 GW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 9.8 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.5 °C (2001 to 2025) |
| Cooling degree days | 179 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.17 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does SAP Building 13 use?
We estimate the facility power at about 19 MW. Estimate from building footprint, low confidence.
How close is SAP Building 13 to the power grid?
The nearest high-voltage substation in OpenStreetMap is 110kV-Umspannwerk Östringen (110 kV), about 4.8 km away.
How clean is the power for SAP Building 13?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Data centers near St. Leon-Rot
- SAP Building 6 / 16 298 m · 8 MW
- SAP WDF51 6.0 km · 18 MW
- Wavehouse 16.3 km · 0.7 MW
- nexspace data centers Heidelberg 17.2 km · 0.9 MW
- Scientific Computing Center 22.2 km · 1.3 MW
- TelemaxX IPC5 22.6 km · 4 MW
- Scientific Computing Center - KIT CN 22.8 km
- euNetworks Colocation Mannheim 26.6 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.