SU Green Data Center

SU Green Data Center is an operational data center operated by Syracuse University in Onondaga, United States. Our footprint estimate of its power is about 2 MW.

Key facts

StatusOperational
OperatorSyracuse University
Facility power2 MW (range 1 MW to 3.2 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 1,652 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 850 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressSkytop Road 623, 13210, Onondaga
Coordinates43.01208, -76.11593

Power and grid

Nearest high-voltage substationOCRRA, 115 kV, 800 m away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationLafayette Station, 345 kV, 4.4 km away
HV substations within 10 km24
UtilityNiagara Mohawk Power Corp. (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityNYIS
Nearest gas pipelineTennessee Gas Pipeline, interstate pipeline, 11.7 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km496 MW in 42 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity268 g CO₂ per kWh (New York, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 45.4%, nuclear 20.7%, hydro 18.5%, solar 7.6%, wind 5%. Clean power: 52.9%
Industrial power priceUSD 0.105 per kWh (New York, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature8.8 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.3 °C (2001 to 2025)
Cooling degree days365 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.58 kWh per m² per day
Wind at 50 m4.8 m/s average
Water stress todayLow - Medium (10-20%) (New York)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does SU Green Data Center use?

We estimate the facility power at about 2 MW. Estimate from building footprint, low confidence.

How close is SU Green Data Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is OCRRA (115 kV), about 800 m away. The local utility is Niagara Mohawk Power Corp., in the NYIS balancing area.

How clean is the power for SU Green Data Center?

The grid in New York emits about 268 g CO₂ per kWh (2025). Largest sources: gas 45.4%, nuclear 20.7%, hydro 18.5%.

Who operates SU Green Data Center?

Syracuse University.