Switch Datacenters AMS4

Switch Datacenters AMS4 is an operational data center operated by Switch Datacenters in Diemen, Netherlands. Our footprint estimate of its power is about 5.4 MW.

Key facts

StatusOperational
OperatorSwitch Datacenters
Facility power5.4 MW (range 2.7 MW to 8.7 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 4,509 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 2,300 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Opened2023
Coordinates52.33151, 4.97360

Power and grid

Nearest high-voltage substation150 kV Venserweg, 150 kV, 600 m away (TenneT)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substation380 kV Diemen, 380 kV, 2.8 km away
HV substations within 10 km19
Power plants within 50 km3.9 GW in 62 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity254 g CO₂ per kWh (Netherlands, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2%
Industrial power priceEUR 0.139 per kWh (Netherlands, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature32.1 °C (2001 to 2025)
Cooling degree days53 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.97 kWh per m² per day
Wind at 50 m7.5 m/s average
Water stress todayLow - Medium (10-20%) (Netherlands)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Switch Datacenters AMS4 use?

We estimate the facility power at about 5.4 MW. Estimate from building footprint, low confidence.

How close is Switch Datacenters AMS4 to the power grid?

The nearest high-voltage substation in OpenStreetMap is 150 kV Venserweg (150 kV), about 600 m away.

How clean is the power for Switch Datacenters AMS4?

The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.

Who operates Switch Datacenters AMS4?

Switch Datacenters.