Telecom Italia Sparkle Milano Data Center
Telecom Italia Sparkle Milano Data Center is an operational data center operated by Telecom Italia Sparkle in Milan, Italy. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Telecom Italia Sparkle |
| Networks | 6 networks PeeringDB. |
| Address | Via Strada Antica di Cassano, 8, Cassina de' Pecchi |
| Coordinates | 45.50261, 9.34278 |
| Website | tisparkle.com |
Power and grid
| Nearest high-voltage substation | Vignate, 132 kV, 1.5 km away (Enel Distribuzione) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Brugherio - Smistamento elettrico TERNA, 380 kV, 7.2 km away |
| HV substations within 10 km | 37 |
| Power plants within 50 km | 6.9 GW in 20 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 13.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 38.5 °C (2001 to 2025) |
| Cooling degree days | 503 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.78 kWh per m² per day |
| Wind at 50 m | 3.1 m/s average |
| Water stress today | High (40-80%) (Italy) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Telecom Italia Sparkle Milano Data Center to the power grid?
The nearest high-voltage substation in OpenStreetMap is Vignate (132 kV), about 1.5 km away.
How clean is the power for Telecom Italia Sparkle Milano Data Center?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Who operates Telecom Italia Sparkle Milano Data Center?
Telecom Italia Sparkle.
Data centers near Milan
- Equinix ML4 - Milan, Cascia 7.8 km
- Microsoft data center in Paullo 8.8 km · 8.6 MW
- MOMIT Milan 9.0 km
- Data center in San Donato Milanese 11.2 km
- TWT Datacenter 12.7 km
- WIIT Milano 12.8 km
- Templus DC Milan MIL01 12.8 km
- Equinix ML2 - Milan, Savona 16.4 km
More Telecom Italia Sparkle data centers
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.