The Bunker (Ash)
The Bunker (Ash) is an operational data center operated by The Bunker Secure Hosting in Sandwich, United Kingdom. Our footprint estimate of its power is about 1.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | The Bunker Secure Hosting |
| Facility power | 1.3 MW (range 0.7 MW to 2.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,111 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 560 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 4 networks PeeringDB. |
| Also known as | The Bunker - South East Data Centre |
| Address | Ash Radar Station, Marshborough Road |
| Coordinates | 51.27111, 1.29581 |
| Website | thebunker.net |
Power and grid
| Nearest high-voltage substation | Richborough Grid, 132 kV, 5.4 km away (UK Power Networks) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | NEMO Link converter station, 400 kV, 5.6 km away |
| HV substations within 10 km | 6 |
| Power plants within 50 km | 4.7 GW in 41 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 11.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 27.5 °C (2001 to 2025) |
| Cooling degree days | 22 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.97 kWh per m² per day |
| Wind at 50 m | 7.9 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does The Bunker (Ash) use?
We estimate the facility power at about 1.3 MW. Estimate from building footprint, low confidence.
How close is The Bunker (Ash) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Richborough Grid (132 kV), about 5.4 km away.
How clean is the power for The Bunker (Ash)?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Who operates The Bunker (Ash)?
The Bunker Secure Hosting.
Data centers near Sandwich
- Sota Datacentre 39.9 km · 6 MW
- Kent Science Park 39.9 km
- Custodian CDC Maidstone 1 51.9 km
- CXD Infrastructure Solutions 52.1 km · 5.6 MW
- CityFibre Cabinets 56.1 km
- EXA Edge DC Wickford 68.0 km
- SDC Colchester1 77.0 km
- CSD Network Services Ltd 86.2 km
More The Bunker Secure Hosting data centers
- Venture West United Kingdom
- The Bunker (Newbury) United Kingdom
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.