TI Sparkle Greece (IDC)
TI Sparkle Greece (IDC) is an operational data center operated by TI Sparkle Greece in Metamorfosi, Greece. Our footprint estimate of its power is about 2 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | TI Sparkle Greece |
| Facility power | 2 MW (range 1 MW to 3.1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 1,633 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 850 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 37 networks, 5 internet exchanges PeeringDB. |
| Also known as | Med Nautilus |
| Address | Ermou 37 |
| Coordinates | 38.07249, 23.77406 |
| Website | tisparkle.com/greece |
Power and grid
| Nearest high-voltage substation | ΚΥΤ ΑΧΑΡΝΩΝ, 400 kV, 4.7 km away (IPTO) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 2 |
| Power plants within 50 km | 2.0 GW in 6 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 325 g CO₂ per kWh (Greece, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 40.3%, wind 20.9%, solar 19.7%, oil and other fossil 7.2%, hydro 5.9%. Clean power: 47.7% |
| Industrial power price | EUR 0.143 per kWh (Greece, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 17.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.6 °C (2001 to 2025) |
| Cooling degree days | 1,096 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.55 kWh per m² per day |
| Wind at 50 m | 5.8 m/s average |
| Water stress today | Extremely High (>80%) (Attica) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does TI Sparkle Greece (IDC) use?
We estimate the facility power at about 2 MW. Estimate from building footprint, low confidence.
How close is TI Sparkle Greece (IDC) to the power grid?
The nearest high-voltage substation in OpenStreetMap is ΚΥΤ ΑΧΑΡΝΩΝ (400 kV), about 4.7 km away.
How clean is the power for TI Sparkle Greece (IDC)?
The grid in Greece emits about 325 g CO₂ per kWh (2025). Largest sources: gas 40.3%, wind 20.9%, solar 19.7%.
Who operates TI Sparkle Greece (IDC)?
TI Sparkle Greece.
Data centers near Metamorfosi
- Lancom Athens DC 4.4 km
- Cloud Module 1 4.5 km
- Data center in Kryonéri 9.5 km
- Εθνικό Ίδρυμα Ερευνών / National Hellenic Research Foundation (EIE/NHRF) 11.3 km
- Digital Realty ATH1/2/3 - Athens 23.9 km · 3.8 MW