Digital Realty ATH1/2/3 - Athens
Digital Realty ATH1/2/3 - Athens is an operational data center operated by Digital Realty in Koropi, Greece. Our footprint estimate of its power is about 3.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Digital Realty |
| Facility power | 3.8 MW (range 1.9 MW to 6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,150 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,600 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 46 networks, 4 internet exchanges PeeringDB. |
| Also known as | Athens 3 · Athens 1 · Athens 2 |
| Address | Ifestou 76 |
| Coordinates | 37.87134, 23.87025 |
| Website | digitalrealty.com/data-centers/emea/athens |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 150 kV, 7.1 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | ΚΥΤ ΑΡΓΥΡΟΥΠΟΛΗΣ, 400 kV, 11 km away |
| HV substations within 10 km | 2 |
| Power plants within 50 km | 945 MW in 2 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 325 g CO₂ per kWh (Greece, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 40.3%, wind 20.9%, solar 19.7%, oil and other fossil 7.2%, hydro 5.9%. Clean power: 47.7% |
| Industrial power price | EUR 0.143 per kWh (Greece, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 17.9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.6 °C (2001 to 2025) |
| Cooling degree days | 1,096 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.55 kWh per m² per day |
| Wind at 50 m | 5.8 m/s average |
| Water stress today | Extremely High (>80%) (Attica) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Digital Realty ATH1/2/3 - Athens use?
We estimate the facility power at about 3.8 MW. Estimate from building footprint, low confidence.
How close is Digital Realty ATH1/2/3 - Athens to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (150 kV), about 7.1 km away.
How clean is the power for Digital Realty ATH1/2/3 - Athens?
The grid in Greece emits about 325 g CO₂ per kWh (2025). Largest sources: gas 40.3%, wind 20.9%, solar 19.7%.
Who operates Digital Realty ATH1/2/3 - Athens?
Digital Realty.
Data centers near Koropi
- Εθνικό Ίδρυμα Ερευνών / National Hellenic Research Foundation (EIE/NHRF) 15.8 km
- Cloud Module 1 19.4 km
- Lancom Athens DC 19.7 km
- TI Sparkle Greece (IDC) 23.9 km · 2 MW
- Data center in Kryonéri 30.0 km
More Digital Realty data centers
- Digital Realty CH1 - Chicago United States
- Digital Realty IAD39 United States
- Digital Realty IAD51 United States
- Digital Realty IAD44 United States
- Digital Realty IAD41 United States
- Digital Realty Singapore SIN11 Singapore
- Digital Realty Toronto YYZ11 Canada
- Digital Realty IAD43 United States
Sources