Travelers Insurance
Travelers Insurance is an operational data center operated by Travelers Insurance in Chalco, United States. Our footprint estimate of its power is about 17 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Travelers Insurance |
| Facility power | 17 MW (range 8.4 MW to 27 MW) Estimate from building footprint, low confidence. Footprint estimate: about 13,944 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 7,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 41.12787, -96.14507 |
Power and grid
| Nearest high-voltage substation | Hwy 50 Substation, 161 kV, 500 m away (Omaha Public Power District) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 345 kV, 900 m away |
| HV substations within 10 km | 19 |
| Utility | Omaha Public Power District (political subdivision) Electric retail service territory (HIFLD, US government). |
| Balancing authority | SWPP |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 600 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.2 GW in 10 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 460 g CO₂ per kWh (Nebraska, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 46%, wind 29.4%, nuclear 17.4%, gas 3.2%, hydro 2.9%. Clean power: 50.7% |
| Industrial power price | USD 0.084 per kWh (Nebraska, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 43.1 °C (2001 to 2025) |
| Cooling degree days | 707 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.16 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Extremely High (>80%) (Nebraska) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Travelers Insurance use?
We estimate the facility power at about 17 MW. Estimate from building footprint, low confidence.
How close is Travelers Insurance to the power grid?
The nearest high-voltage substation in OpenStreetMap is Hwy 50 Substation (161 kV), about 500 m away. The local utility is Omaha Public Power District, in the SWPP balancing area.
How clean is the power for Travelers Insurance?
The grid in Nebraska emits about 460 g CO₂ per kWh (2025). Largest sources: coal 46%, wind 29.4%, nuclear 17.4%.
Who operates Travelers Insurance?
Travelers Insurance.
Data centers near Chalco
- Sarpy Meta Data Center 680 m · 52 MW
- Google 788 m · 25 MW
- Google Papillion Data Center 981 m · 113 MW
- Sarpy Meta Data Center 1.2 km · 56 MW
- Google 1.2 km · 25 MW
- Google 1.2 km · 25 MW
- Meta Sarpy Data center 1.5 km · 151 MW
- Sarpy Meta Data Center 1.7 km · 128 MW
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.