UHG Data Center
UHG Data Center is an operational data center in Chaska, United States. Our footprint estimate of its power is about 38 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 38 MW (range 19 MW to 60 MW) Estimate from building footprint, low confidence. Footprint estimate: about 31,501 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 16,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | West Creek Lane 1707, 55318, Chaska |
| Coordinates | 44.80833, -93.63430 |
Power and grid
| Utility | City Of Chaska (municipal) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | MISO |
| Nearest gas pipeline | Northern Natural Gas Co, interstate pipeline, 9.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 344 g CO₂ per kWh (Minnesota, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 25.1%, coal 23%, nuclear 21.5%, gas 20.7%, solar 5.9%. Clean power: 55.8% |
| Industrial power price | USD 0.100 per kWh (Minnesota, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41.6 °C (2001 to 2025) |
| Cooling degree days | 347 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.8 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Medium - High (20-40%) (Minnesota) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does UHG Data Center use?
We estimate the facility power at about 38 MW. Estimate from building footprint, low confidence.
How clean is the power for UHG Data Center?
The grid in Minnesota emits about 344 g CO₂ per kWh (2025). Largest sources: wind 25.1%, coal 23%, nuclear 21.5%.
Data centers near Chaska
- Stream Data Centers - MN I 208 m · 11 MW
- Flexential - Minneapolis/Chaska (MSP01) 5.5 km · 15 MW
- Centersquare Minneapolis (MSP1) 14.0 km
- US Signal MN01 - Minneapolis 19.4 km
- EdgeConneX Minneapolis (EDCMSP01) 19.8 km
- Verizon - Bloomington Network 20.4 km · 7.4 MW
- NP Belle Plaine (MSP1) 23.4 km
- US Internet - Minnetonka 24.0 km