Unidata IDC-GALERIA
Unidata IDC-GALERIA is an operational data center operated by Unidata in Rome, Italy. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Unidata |
| Networks | 7 networks, 1 internet exchanges PeeringDB. |
| Address | viale Alexandre Gustave Eiffel, 100 |
| Coordinates | 41.80694, 12.33610 |
| Website | unidata.it |
Power and grid
| Nearest high-voltage substation | Acea Fiera di Roma, 150 kV, 900 m away (Acea Distribuzione) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Roma Ovest, 380 kV, 7.8 km away |
| HV substations within 10 km | 19 |
| Power plants within 50 km | 910 MW in 5 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 285 g CO₂ per kWh (Italy, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 47.4%, solar 16.8%, hydro 15.7%, wind 8.1%, bioenergy 5.9%. Clean power: 48.7% |
| Industrial power price | EUR 0.173 per kWh (Italy, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 16 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 40.9 °C (2001 to 2025) |
| Cooling degree days | 805 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.25 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Extremely High (>80%) (Lazio) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is Unidata IDC-GALERIA to the power grid?
The nearest high-voltage substation in OpenStreetMap is Acea Fiera di Roma (150 kV), about 900 m away.
How clean is the power for Unidata IDC-GALERIA?
The grid in Italy emits about 285 g CO₂ per kWh (2025). Largest sources: gas 47.4%, solar 16.8%, hydro 15.7%.
Who operates Unidata IDC-GALERIA?
Unidata.
Data centers near Rome
- Fiber 23 2.5 km
- DC Noovle ROMA 4.7 km
- TIER IV 4.8 km · 87 MW
- Retelit S.p.A. Roma Cornelia 10.0 km
- Cornelia (Rome) 10.1 km
- Data center Roma Capitale 11.4 km
- Digital Realty ROM1 - Rome 13.1 km
- Namex Datacenter Rome 17.8 km
More Unidata data centers