University of Illinois NCSA Delta
University of Illinois NCSA Delta is an operational AI data center operated by University of Illinois Urbana-Champaign (UIUC) in Champaign, United States. Its power is about 0.7 MW. Epoch AI estimates about 212 H100-equivalent AI chips (NVIDIA A100, NVIDIA A40 PCIe).
Key facts
| Status | Operational |
|---|---|
| Operator | University of Illinois Urbana-Champaign (UIUC) |
| Facility power | 0.7 MW Reported (Epoch AI or owner data) |
| AI compute | 212 H100-equivalents |
| AI chips | NVIDIA A100, NVIDIA A40 PCIe Reported (Epoch AI or owner data) |
| Chip count | 880 Largest reported cluster at this site (Epoch AI). |
| GPU capacity if all AI | about 280 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | 1205 W Clark St, Urbana, IL 61801 |
| Coordinates | 40.11492, -88.22489 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 2.1 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Rising Substation, 345 kV, 10.9 km away |
| HV substations within 10 km | 7 |
| Utility | Eastern Illinois Elec Coop (cooperative) Electric retail service territory (HIFLD, US government). |
| Balancing authority | MISO |
| Nearest gas pipeline | Trunkline Gas Co, interstate pipeline, 7.9 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 1.3 GW in 19 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 247 g CO₂ per kWh (Illinois, 2025) Average of all power made in the area. Ember. |
| Grid power mix | nuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3% |
| Industrial power price | USD 0.113 per kWh (Illinois, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 11.4 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 42.1 °C (2001 to 2025) |
| Cooling degree days | 598 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.99 kWh per m² per day |
| Wind at 50 m | 6.8 m/s average |
| Water stress today | Medium - High (20-40%) (Illinois) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
GPU clusters at this site
| Cluster | Chips | Count | Power | Since |
|---|---|---|---|---|
| University of Illinois NCSA Delta | NVIDIA A100 + NVIDIA A40 PCIe | 880 | 0.7 MW | 2022-10-11 |
Source: Epoch AI GPU Clusters.
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does University of Illinois NCSA Delta use?
Public data puts the facility power at about 0.7 MW. Reported (Epoch AI or owner data).
What chips does University of Illinois NCSA Delta use?
Reported chips: NVIDIA A100, NVIDIA A40 PCIe.
How close is University of Illinois NCSA Delta to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 2.1 km away. The local utility is Eastern Illinois Elec Coop, in the MISO balancing area.
How clean is the power for University of Illinois NCSA Delta?
The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.
Who operates University of Illinois NCSA Delta?
University of Illinois Urbana-Champaign (UIUC).
Data centers near Champaign
- NCSA Petascale Computing Facility 2.6 km · 3.9 MW