University of Illinois NCSA Delta

University of Illinois NCSA Delta is an operational AI data center operated by University of Illinois Urbana-Champaign (UIUC) in Champaign, United States. Its power is about 0.7 MW. Epoch AI estimates about 212 H100-equivalent AI chips (NVIDIA A100, NVIDIA A40 PCIe).

Key facts

StatusOperational
OperatorUniversity of Illinois Urbana-Champaign (UIUC)
Facility power0.7 MW
Reported (Epoch AI or owner data)
AI compute212 H100-equivalents
AI chipsNVIDIA A100, NVIDIA A40 PCIe
Reported (Epoch AI or owner data)
Chip count880
Largest reported cluster at this site (Epoch AI).
GPU capacity if all AIabout 280 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Address1205 W Clark St, Urbana, IL 61801
Coordinates40.11492, -88.22489

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 2.1 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationRising Substation, 345 kV, 10.9 km away
HV substations within 10 km7
UtilityEastern Illinois Elec Coop (cooperative)
Electric retail service territory (HIFLD, US government).
Balancing authorityMISO
Nearest gas pipelineTrunkline Gas Co, interstate pipeline, 7.9 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km1.3 GW in 19 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity247 g CO₂ per kWh (Illinois, 2025)
Average of all power made in the area. Ember.
Grid power mixnuclear 49.9%, gas 16.6%, coal 15.8%, wind 12.8%, solar 4.5%. Clean power: 67.3%
Industrial power priceUSD 0.113 per kWh (Illinois, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature11.4 °C
NASA POWER, average of 2001 to 2025.
Highest temperature42.1 °C (2001 to 2025)
Cooling degree days598 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.99 kWh per m² per day
Wind at 50 m6.8 m/s average
Water stress todayMedium - High (20-40%) (Illinois)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Medium - High (20-40%)
Business-as-usual scenario.

GPU clusters at this site

ClusterChipsCountPowerSince
University of Illinois NCSA DeltaNVIDIA A100 + NVIDIA A40 PCIe8800.7 MW2022-10-11

Source: Epoch AI GPU Clusters.

Satellite view

Questions

How much power does University of Illinois NCSA Delta use?

Public data puts the facility power at about 0.7 MW. Reported (Epoch AI or owner data).

What chips does University of Illinois NCSA Delta use?

Reported chips: NVIDIA A100, NVIDIA A40 PCIe.

How close is University of Illinois NCSA Delta to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 2.1 km away. The local utility is Eastern Illinois Elec Coop, in the MISO balancing area.

How clean is the power for University of Illinois NCSA Delta?

The grid in Illinois emits about 247 g CO₂ per kWh (2025). Largest sources: nuclear 49.9%, gas 16.6%, coal 15.8%.

Who operates University of Illinois NCSA Delta?

University of Illinois Urbana-Champaign (UIUC).