Vaultica Data Centers | OSL01
Vaultica Data Centers | OSL01 is an operational data center operated by Vaultica Data Centers - NORDICS in Oslo, Norway. Our footprint estimate of its power is about 25 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Vaultica Data Centers - NORDICS |
| Facility power | 25 MW (range 13 MW to 40 MW) Estimate from building footprint, low confidence. Footprint estimate: about 5,243 m² building outline x 4 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 11,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 53 networks, 4 internet exchanges PeeringDB. |
| Also known as | Stack Infrastructure OSLO1A |
| Address | 1 Selma Ellefsens Vei |
| Coordinates | 59.92506, 10.80912 |
| Website | vaultica.com/norway/#OSL01 |
Power and grid
| Nearest high-voltage substation | Ulven trafostasjon, 300 kV, 400 m away (Statnett;Elvia) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 24 |
| Power plants within 50 km | 173 MW in 14 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 28 g CO₂ per kWh (Norway, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 89.9%, wind 8.4%, gas 0.6%. Clean power: 99% |
| Industrial power price | EUR 0.097 per kWh (Norway, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.1 °C (2001 to 2025) |
| Cooling degree days | 22 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.55 kWh per m² per day |
| Wind at 50 m | 3.9 m/s average |
| Water stress today | Low - Medium (10-20%) (Oslo) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Vaultica Data Centers | OSL01 use?
We estimate the facility power at about 25 MW. Estimate from building footprint, low confidence.
How close is Vaultica Data Centers | OSL01 to the power grid?
The nearest high-voltage substation in OpenStreetMap is Ulven trafostasjon (300 kV), about 400 m away.
How clean is the power for Vaultica Data Centers | OSL01?
The grid in Norway emits about 28 g CO₂ per kWh (2025). Largest sources: hydro 89.9%, wind 8.4%, gas 0.6%.
Who operates Vaultica Data Centers | OSL01?
Vaultica Data Centers - NORDICS.
Data centers near Oslo
- Rent a Rack 104 m
- Arelion Oslo OKR/C 387 m
- Fujitsu Oslo 1.5 km
- Globalconnect Oslo (HMG1) 1.8 km
- Verizon HMG9 Oslo 2.1 km · 8.9 MW
- GlobalConnect Nydalen 3.5 km
- Blix CJH Oslo 3.9 km
- Blix BDC Oslo 4.4 km
More Vaultica Data Centers - NORDICS data centers
- STACK EMEA - OSL03 Norway
- Vaultica Data Centers | COP01 Denmark
- Vaultica Data Centers | OSL02 Norway
- Vaultica Data Centers | STO01 Sweden