Verizon HMG9 Oslo
Verizon HMG9 Oslo is an operational data center operated by Verizon Communications in Oslo, Norway. Our footprint estimate of its power is about 8.9 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Verizon Communications |
| Facility power | 8.9 MW (range 4.5 MW to 14 MW) Estimate from building footprint, low confidence. Footprint estimate: about 7,422 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 45 networks, 5 internet exchanges PeeringDB. |
| Also known as | GlobalConnect Oslo (HMG9) · Bulk Oslo Internet Exchange - OS-IX · Bulk Data Centers Oslo Internet Exchange |
| Address | Hans Moller Gasmansvei 9 |
| Coordinates | 59.93843, 10.83497 |
| Website | globalconnect.se/tjanster/colocation |
Power and grid
| Nearest high-voltage substation | Ulven trafostasjon, 300 kV, 2.3 km away (Statnett;Elvia) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 24 |
| Power plants within 50 km | 173 MW in 14 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 28 g CO₂ per kWh (Norway, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 89.9%, wind 8.4%, gas 0.6%. Clean power: 99% |
| Industrial power price | EUR 0.097 per kWh (Norway, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 5 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 32.1 °C (2001 to 2025) |
| Cooling degree days | 22 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.55 kWh per m² per day |
| Wind at 50 m | 3.9 m/s average |
| Water stress today | Low - Medium (10-20%) (Oslo) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Verizon HMG9 Oslo use?
We estimate the facility power at about 8.9 MW. Estimate from building footprint, low confidence.
How close is Verizon HMG9 Oslo to the power grid?
The nearest high-voltage substation in OpenStreetMap is Ulven trafostasjon (300 kV), about 2.3 km away.
How clean is the power for Verizon HMG9 Oslo?
The grid in Norway emits about 28 g CO₂ per kWh (2025). Largest sources: hydro 89.9%, wind 8.4%, gas 0.6%.
Who operates Verizon HMG9 Oslo?
Verizon Communications.
Data centers near Oslo
- Globalconnect Oslo (HMG1) 266 m
- Arelion Oslo OKR/C 1.7 km
- Rent a Rack 2.0 km
- Vaultica Data Centers | OSL01 2.1 km · 25 MW
- Blix BDC Oslo 2.8 km
- Fujitsu Oslo 3.3 km
- GlobalConnect Nydalen 3.9 km
- Blix NR5 Oslo 4.8 km
More Verizon Communications data centers
- Verizon Istanbul Türkiye
- MCI Stockholm (Kista) Sweden
- MCI/Verizon Brussels (Diegem) E Belgium
- MCI/Verizon Paris St Denis France
- Verizon Atlanta United States
- Verizon Madrid Spain
- XO Salt Lake City IP PoP United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.