Wroclaw Centre for Networking and Supercomputing Lem

Wroclaw Centre for Networking and Supercomputing Lem is an operational AI data center operated by Wroclaw Tech (Wrocław University of Science and Technology) in Wrocław, Poland. Its power is about 0.4 MW. Epoch AI estimates about 304 H100-equivalent AI chips (NVIDIA H100 SXM5 80GB).

Key facts

StatusOperational
OperatorWroclaw Tech (Wrocław University of Science and Technology)
Facility power0.4 MW
Reported (Epoch AI or owner data)
AI compute304 H100-equivalents
AI chipsNVIDIA H100 SXM5 80GB
Reported (Epoch AI or owner data)
Chip count304
Largest reported cluster at this site (Epoch AI).
GPU capacity if all AIabout 190 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Addressplac Grunwaldzki 9, 50-366 Wrocław, Poland
Coordinates51.10983, 17.05753

Power and grid

Nearest high-voltage substationStacja elektroenergetyczna 110/20kV „GPZ Walecznych”, 110 kV, 1.1 km away (Tauron)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationStacja elektroenergetyczna 400/110kV „SE Pasikurowice”, 400 kV, 12.3 km away
HV substations within 10 km20
Power plants within 50 km457 MW in 7 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity591 g CO₂ per kWh (Poland, 2025)
Average of all power made in the area. Ember.
Grid power mixcoal 50.6%, gas 14.4%, wind 13.9%, solar 11.3%, bioenergy 4.9%. Clean power: 31.2%
Industrial power priceEUR 0.169 per kWh (Poland, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature9.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature37.8 °C (2001 to 2025)
Cooling degree days200 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy3.02 kWh per m² per day
Wind at 50 m6.3 m/s average
Water stress todayLow - Medium (10-20%) (Poland)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

GPU clusters at this site

ClusterChipsCountPowerSince
Wroclaw Centre for Networking and Supercomputing LemNVIDIA H100 SXM5 80GB3040.4 MW2024-06-01

Source: Epoch AI GPU Clusters.

Satellite view

Questions

How much power does Wroclaw Centre for Networking and Supercomputing Lem use?

Public data puts the facility power at about 0.4 MW. Reported (Epoch AI or owner data).

What chips does Wroclaw Centre for Networking and Supercomputing Lem use?

Reported chips: NVIDIA H100 SXM5 80GB.

How close is Wroclaw Centre for Networking and Supercomputing Lem to the power grid?

The nearest high-voltage substation in OpenStreetMap is Stacja elektroenergetyczna 110/20kV „GPZ Walecznych” (110 kV), about 1.1 km away.

How clean is the power for Wroclaw Centre for Networking and Supercomputing Lem?

The grid in Poland emits about 591 g CO₂ per kWh (2025). Largest sources: coal 50.6%, gas 14.4%, wind 13.9%.

Who operates Wroclaw Centre for Networking and Supercomputing Lem?

Wroclaw Tech (Wrocław University of Science and Technology).