5GN Sydney Data Centre (SDC)
5GN Sydney Data Centre (SDC) is an operational data center operated by 5G Networks in Pyrmont, Australia. Our footprint estimate of its power is about 36 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | 5G Networks |
| Facility power | 36 MW (range 18 MW to 58 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,995 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 15,000 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 10 networks, 1 internet exchanges PeeringDB. |
| Also known as | Verizon Data Centre |
| Address | 55 Pyrmont Bridge Rd |
| Coordinates | -33.87234, 151.19467 |
| Website | 5gnetworks.com.au |
Power and grid
| Nearest high-voltage substation | Pyrmont Subtransmission Substation, 132 kV, 300 m away (Ausgrid) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Haymarket Bulk Supply Substation, 330 kV, 1.2 km away |
| HV substations within 10 km | 41 |
| Power plants within 50 km | 179 MW in 4 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 518 g CO₂ per kWh (Australia, 2025) Average of all power made in the area. Ember. |
| Grid power mix | coal 42.9%, solar 20.4%, gas 15.5%, wind 13.8%, hydro 4.4%. Clean power: 39.8% |
Climate and water
| Average temperature | 18.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.9 °C (2001 to 2025) |
| Cooling degree days | 673 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.65 kWh per m² per day |
| Wind at 50 m | 5.2 m/s average |
| Water stress today | High (40-80%) (New South Wales) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | High (40-80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does 5GN Sydney Data Centre (SDC) use?
We estimate the facility power at about 36 MW. Estimate from building footprint, low confidence.
How close is 5GN Sydney Data Centre (SDC) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Pyrmont Subtransmission Substation (132 kV), about 300 m away.
How clean is the power for 5GN Sydney Data Centre (SDC)?
The grid in Australia emits about 518 g CO₂ per kWh (2025). Largest sources: coal 42.9%, solar 20.4%, gas 15.5%.
Who operates 5GN Sydney Data Centre (SDC)?
5G Networks.
Data centers near Pyrmont
- DigiCo Sydney SYD1 (formerly Global Switch Australia) 457 m · 76 MW
- Optus Ultimo 802 m · 8.1 MW
- Powertel Data Centre 1.2 km
- PIPE Networks Sydney 1.2 km
- TPG Data Centre 1.3 km
- Spectrum Networks George Street Data Center 1.3 km
- Intellicentre 1 (IC1) 1.4 km
- Payam Data Recovery 1.4 km
More 5G Networks data centers
- 5GN Brisbane Data Centre (BDC) Australia
- 5GN Melbourne Data Centre (MDC) Australia
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.