Data Center Directory

AT&T Center

AT&T Center is an operational data center operated by American Telephone & Telegraph in San Diego, United States. Our footprint estimate of its power is about 9.8 MW.

Key facts

StatusOperational
OperatorAmerican Telephone & Telegraph
Facility power9.8 MW (range 4.9 MW to 16 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 8,150 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 4,200 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
AddressRobinson Avenue 650, 92103, San Diego
Coordinates32.74765, -117.15895

Power and grid

Nearest high-voltage substationOld Town Substation, 230 kV, 3.7 km away (San Diego Gas & Electric)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km3
UtilitySan Diego Gas & Electric Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityCISO
Nearest gas pipelineSan Diego Gas & Elec Co, intrastate pipeline, 1.9 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km5.2 GW in 40 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature17 °C
NASA POWER, average of 2001 to 2025.
Highest temperature40.9 °C (2001 to 2025)
Cooling degree days692 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.82 kWh per m² per day
Wind at 50 m3.8 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does AT&T Center use?

We estimate the facility power at about 9.8 MW. Estimate from building footprint, low confidence.

How close is AT&T Center to the power grid?

The nearest high-voltage substation in OpenStreetMap is Old Town Substation (230 kV), about 3.7 km away. The local utility is San Diego Gas & Electric Co, in the CISO balancing area.

How clean is the power for AT&T Center?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates AT&T Center?

American Telephone & Telegraph.

Data centers near San Diego

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.