EdgeConneX San Diego (EDCSDG01)
EdgeConneX San Diego (EDCSDG01) is an operational data center operated by EdgeConneX in San Diego, United States. Our footprint estimate of its power is about 5.4 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | EdgeConneX |
| Facility power | 5.4 MW (range 2.7 MW to 8.6 MW) Estimate from building footprint, low confidence. Footprint estimate: about 4,476 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 2,300 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 8 networks PeeringDB. |
| Also known as | EdgeConneX San Diego |
| Address | 5761 Copley Dr |
| Coordinates | 32.84049, -117.16837 |
| Website | edgeconnex.com |
Power and grid
| Nearest high-voltage substation | Mission Substation, 230 kV, 6.7 km away (San Diego Gas & Electric) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 4 |
| Utility | San Diego Gas & Electric Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | San Diego Gas & Elec Co, intrastate pipeline, 1.8 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.1 GW in 50 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 17.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 43.8 °C (2001 to 2025) |
| Cooling degree days | 885 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.82 kWh per m² per day |
| Wind at 50 m | 4.2 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does EdgeConneX San Diego (EDCSDG01) use?
We estimate the facility power at about 5.4 MW. Estimate from building footprint, low confidence.
How close is EdgeConneX San Diego (EDCSDG01) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Mission Substation (230 kV), about 6.7 km away. The local utility is San Diego Gas & Electric Co, in the CISO balancing area.
How clean is the power for EdgeConneX San Diego (EDCSDG01)?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates EdgeConneX San Diego (EDCSDG01)?
EdgeConneX.
Data centers near San Diego
- I2B SAN02 3.2 km
- ScaleMatrix San Diego Data Center US-West 01 3.3 km
- I2B SAN01 3.4 km
- LightEdge San Diego 1 (SAN1) 3.9 km · 8.3 MW
- LightEdge San Diego 2 (SAN2) 7.0 km
- AT&T Center 10.4 km · 9.8 MW
- SDSU Computer Room 11.7 km
- DataBank San Diego (SAN1) 18.7 km
More EdgeConneX data centers
- EdgeConneX PHX02 Data Center United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex DUB04 Ireland
- EdgeConneX Germany
- EdgeConneX Chicago (EDCCHI02) United States
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConneX data center in Oosteinde Netherlands
- EdgeConnex - DEN02 United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.