LightEdge San Diego 1 (SAN1)
LightEdge San Diego 1 (SAN1) is an operational data center operated by LightEdge NFINIT in San Diego, United States. Our footprint estimate of its power is about 8.3 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | LightEdge NFINIT |
| Facility power | 8.3 MW (range 4.1 MW to 13 MW) Estimate from building footprint, low confidence. Footprint estimate: about 6,903 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 3,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 8 networks PeeringDB. |
| Also known as | LightEdge SAN1 |
| Address | 9305 Lightwave Ave |
| Coordinates | 32.82807, -117.12991 |
| Website | lightedge.com |
Power and grid
| Nearest high-voltage substation | Mission Substation, 230 kV, 4.7 km away (San Diego Gas & Electric) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 3 |
| Utility | San Diego Gas & Electric Co (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | CISO |
| Nearest gas pipeline | San Diego Gas & Elec Co, intrastate pipeline, 200 m away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 4.1 GW in 50 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 189 g CO₂ per kWh (California, 2025) Average of all power made in the area. Ember. |
| Grid power mix | solar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7% |
| Industrial power price | USD 0.241 per kWh (California, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 17.1 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 43.8 °C (2001 to 2025) |
| Cooling degree days | 885 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 5.82 kWh per m² per day |
| Wind at 50 m | 4.2 m/s average |
| Water stress today | Extremely High (>80%) (California) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Extremely High (>80%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does LightEdge San Diego 1 (SAN1) use?
We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.
How close is LightEdge San Diego 1 (SAN1) to the power grid?
The nearest high-voltage substation in OpenStreetMap is Mission Substation (230 kV), about 4.7 km away. The local utility is San Diego Gas & Electric Co, in the CISO balancing area.
How clean is the power for LightEdge San Diego 1 (SAN1)?
The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.
Who operates LightEdge San Diego 1 (SAN1)?
LightEdge NFINIT.
Data centers near San Diego
- I2B SAN01 483 m
- I2B SAN02 699 m
- ScaleMatrix San Diego Data Center US-West 01 1.2 km
- EdgeConneX San Diego (EDCSDG01) 3.9 km · 5.4 MW
- SDSU Computer Room 8.1 km
- AT&T Center 9.3 km · 9.8 MW
- LightEdge San Diego 2 (SAN2) 10.2 km
- DataBank San Diego (SAN1) 18.6 km
More LightEdge NFINIT data centers
- LightEdge San Diego 2 (SAN2) United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.