LightEdge San Diego 1 (SAN1)

LightEdge San Diego 1 (SAN1) is an operational data center operated by LightEdge NFINIT in San Diego, United States. Our footprint estimate of its power is about 8.3 MW.

Key facts

StatusOperational
OperatorLightEdge NFINIT
Facility power8.3 MW (range 4.1 MW to 13 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 6,903 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks8 networks
PeeringDB.
Also known asLightEdge SAN1
Address9305 Lightwave Ave
Coordinates32.82807, -117.12991
Websitelightedge.com

Power and grid

Nearest high-voltage substationMission Substation, 230 kV, 4.7 km away (San Diego Gas & Electric)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
HV substations within 10 km3
UtilitySan Diego Gas & Electric Co (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityCISO
Nearest gas pipelineSan Diego Gas & Elec Co, intrastate pipeline, 200 m away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km4.1 GW in 50 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity189 g CO₂ per kWh (California, 2025)
Average of all power made in the area. Ember.
Grid power mixsolar 37.4%, gas 30.4%, hydro 11.7%, nuclear 7.3%, wind 6.7%. Clean power: 69.7%
Industrial power priceUSD 0.241 per kWh (California, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature17.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature43.8 °C (2001 to 2025)
Cooling degree days885 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy5.82 kWh per m² per day
Wind at 50 m4.2 m/s average
Water stress todayExtremely High (>80%) (California)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Extremely High (>80%)
Business-as-usual scenario.

Satellite view

Questions

How much power does LightEdge San Diego 1 (SAN1) use?

We estimate the facility power at about 8.3 MW. Estimate from building footprint, low confidence.

How close is LightEdge San Diego 1 (SAN1) to the power grid?

The nearest high-voltage substation in OpenStreetMap is Mission Substation (230 kV), about 4.7 km away. The local utility is San Diego Gas & Electric Co, in the CISO balancing area.

How clean is the power for LightEdge San Diego 1 (SAN1)?

The grid in California emits about 189 g CO₂ per kWh (2025). Largest sources: solar 37.4%, gas 30.4%, hydro 11.7%.

Who operates LightEdge San Diego 1 (SAN1)?

LightEdge NFINIT.