Data Center Directory

EdgeConneX data center in Oosteinde

EdgeConneX data center in Oosteinde is an operational data center operated by EdgeConneX in Oosteinde, Netherlands. Our footprint estimate of its power is about 14 MW.

Key facts

StatusOperational
OperatorEdgeConneX
Facility power14 MW (range 6.8 MW to 22 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 11,372 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 6,000 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Also known asEdgeConneX AMS02
Opened2000
Coordinates52.28292, 4.76778

Power and grid

Nearest high-voltage substation150 kV Koolhovenlaan, 150 kV, 300 m away (EdgeConnex)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationUnnamed substation, 380 kV, 9 km away
HV substations within 10 km7
Power plants within 50 km4.7 GW in 59 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity254 g CO₂ per kWh (Netherlands, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2%
Industrial power priceEUR 0.139 per kWh (Netherlands, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature32.1 °C (2001 to 2025)
Cooling degree days53 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.97 kWh per m² per day
Wind at 50 m7.5 m/s average
Water stress todayLow - Medium (10-20%) (Netherlands)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does EdgeConneX data center in Oosteinde use?

We estimate the facility power at about 14 MW. Estimate from building footprint, low confidence.

How close is EdgeConneX data center in Oosteinde to the power grid?

The nearest high-voltage substation in OpenStreetMap is 150 kV Koolhovenlaan (150 kV), about 300 m away.

How clean is the power for EdgeConneX data center in Oosteinde?

The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.

Who operates EdgeConneX data center in Oosteinde?

EdgeConneX.

Data centers near Oosteinde

More EdgeConneX data centers

Sources

Correct this page or get the data

Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.