maincubes AMS01

maincubes AMS01 is an operational data center operated by Maincubes in Schiphol Rijk, Netherlands. Our footprint estimate of its power is about 8.1 MW.

Key facts

StatusOperational
OperatorMaincubes
Facility power8.1 MW (range 4.1 MW to 13 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 6,790 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 3,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks37 networks, 4 internet exchanges
PeeringDB.
Also known asMaincubes AMS01 · LeaseWeb AMS-02 · Kolo NL4 Amsterdam
AddressCapronilaan 2
Opened2008
Coordinates52.28219, 4.77286
Websitemaincubes.com

Power and grid

Nearest high-voltage substation150 kV Koolhovenlaan, 150 kV, 500 m away (EdgeConnex)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationUnnamed substation, 380 kV, 9.2 km away
HV substations within 10 km8
Power plants within 50 km4.7 GW in 59 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity254 g CO₂ per kWh (Netherlands, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 34.9%, wind 25%, solar 21.1%, coal 7.1%, bioenergy 5.1%. Clean power: 54.2%
Industrial power priceEUR 0.139 per kWh (Netherlands, 2026-S1)
Non-household users with 20 to 70 GWh per year, without VAT. Eurostat.

Climate and water

Average temperature10.5 °C
NASA POWER, average of 2001 to 2025.
Highest temperature32.1 °C (2001 to 2025)
Cooling degree days53 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.97 kWh per m² per day
Wind at 50 m7.5 m/s average
Water stress todayLow - Medium (10-20%) (Netherlands)
Share of the local water supply that people already use. WRI Aqueduct 4.0, country level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does maincubes AMS01 use?

We estimate the facility power at about 8.1 MW. Estimate from building footprint, low confidence.

How close is maincubes AMS01 to the power grid?

The nearest high-voltage substation in OpenStreetMap is 150 kV Koolhovenlaan (150 kV), about 500 m away.

How clean is the power for maincubes AMS01?

The grid in Netherlands emits about 254 g CO₂ per kWh (2025). Largest sources: gas 34.9%, wind 25%, solar 21.1%.

Who operates maincubes AMS01?

Maincubes.