maincubes FRANKFURT-01
maincubes FRANKFURT-01 is an operational data center operated by Maincubes in Offenbach am Main, Germany. Our footprint estimate of its power is about 2.8 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Maincubes |
| Facility power | 2.8 MW (range 1.4 MW to 4.4 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,292 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 1,200 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Goethering 29, 63067, Offenbach am Main |
| Coordinates | 50.10963, 8.74311 |
| Website | maincubes.com/en/data-centers/frankfurt-01 |
Power and grid
| Nearest high-voltage substation | 110 KV Schaltanlage, 110 kV, 200 m away (Energieversorgung Offenbach) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Frankfurt Nord, 220 kV, 5.5 km away |
| HV substations within 10 km | 31 |
| Power plants within 50 km | 3.0 GW in 44 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 10.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 39.8 °C (2001 to 2025) |
| Cooling degree days | 233 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.98 kWh per m² per day |
| Wind at 50 m | 5.7 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does maincubes FRANKFURT-01 use?
We estimate the facility power at about 2.8 MW. Estimate from building footprint, low confidence.
How close is maincubes FRANKFURT-01 to the power grid?
The nearest high-voltage substation in OpenStreetMap is 110 KV Schaltanlage (110 kV), about 200 m away.
How clean is the power for maincubes FRANKFURT-01?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Who operates maincubes FRANKFURT-01?
Maincubes.
Data centers near Offenbach am Main
- maincubes FRA01 69 m · 2 MW
- Vantage Data Center (FRA1) 77 m · 7.6 MW
- EXA Edge DC Frankfurt1 1.1 km · 16 MW
- Digital Realty Frankfurt FRA1-27 1.2 km · 31 MW
- Digital Realty FRA16 1.2 km · 20 MW
- NTT Frankfurt 2 Data Center (FRA2) 1.3 km · 48 MW
- COLT DC Frankfurt 1.4 km · 2 MW
- iNTERWERK Rechenzentrum 1.4 km · 4 MW
More Maincubes data centers
- maincubes AMS01 Netherlands
- Maincubes FRA02 Germany
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.