BrainServe
BrainServe is an operational data center in Crissier, Switzerland. Our footprint estimate of its power is about 12 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 12 MW (range 5.9 MW to 19 MW) Estimate from building footprint, low confidence. Footprint estimate: about 3,259 m² building outline x 3 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 5,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | Rue de la Vernie 17, Crissier |
| Coordinates | 46.54651, 6.57329 |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 220 kV, 200 m away (Swissgrid) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 6 |
| Power plants within 50 km | 238 MW in 13 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 39 g CO₂ per kWh (Switzerland, 2025) Average of all power made in the area. Ember. |
| Grid power mix | hydro 52.3%, nuclear 29.9%, solar 12.1%, oil and other fossil 1.9%, bioenergy 1.6%. Clean power: 97.7% |
Climate and water
| Average temperature | 9 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.9 °C (2001 to 2025) |
| Cooling degree days | 132 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.59 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Low (<10%) (Vaud) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low (<10%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does BrainServe use?
We estimate the facility power at about 12 MW. Estimate from building footprint, low confidence.
How close is BrainServe to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (220 kV), about 200 m away.
How clean is the power for BrainServe?
The grid in Switzerland emits about 39 g CO₂ per kWh (2025). Largest sources: hydro 52.3%, nuclear 29.9%, solar 12.1%.
Data centers near Crissier
- Brainserve 211 m
- EXA Edge DC Villars-Sainte-Croix 1.8 km
- Swisscom Savoie 4.8 km · 1.3 MW
- AlpineDC 6.0 km
- Wifx Data Center Vaud 25.0 km
- STACK infrastructure GEN02 27.8 km
- NetaPOP Pontarlier 43.4 km
- Equinix GV1 - Geneva, City 50.4 km
Sources
Correct this page or get the data