CDL Strata Campus Data Centre
CDL Strata Campus Data Centre is an operational data center in Stockport, United Kingdom. Our footprint estimate of its power is about 0.6 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 0.6 MW (range 0.3 MW to 1 MW) Estimate from building footprint, low confidence. Footprint estimate: about 511 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 260 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Address | SK4 2HD |
| Coordinates | 53.40822, -2.17900 |
Power and grid
| Nearest high-voltage substation | Bredbury Substation, 275 kV, 3.4 km away (National Grid Electricity Transmission) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| HV substations within 10 km | 11 |
| Power plants within 50 km | 3.1 GW in 75 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 218 g CO₂ per kWh (United Kingdom, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2% |
Climate and water
| Average temperature | 8.7 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 29.7 °C (2001 to 2025) |
| Cooling degree days | 7 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.73 kWh per m² per day |
| Wind at 50 m | 7.3 m/s average |
| Water stress today | Low - Medium (10-20%) (England) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does CDL Strata Campus Data Centre use?
We estimate the facility power at about 0.6 MW. Estimate from building footprint, low confidence.
How close is CDL Strata Campus Data Centre to the power grid?
The nearest high-voltage substation in OpenStreetMap is Bredbury Substation (275 kV), about 3.4 km away.
How clean is the power for CDL Strata Campus Data Centre?
The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.
Data centers near Stockport
- Teledata Manchester - Delta House 6.2 km · 3.4 MW
- Data center in Longsight 6.7 km · 0.9 MW
- Equinix MA4 - Manchester, Synergy House 7.1 km
- Greenheys 7.2 km
- Equinix MA1 - Manchester, Williams/Kilburn 7.2 km
- The UK Grid Network LTD (Greenheys DC) 7.3 km
- iomart DC6 Turing House 7.7 km
- Volta Manchester 7.7 km · 3.9 MW