Teledata Manchester - Delta House

Teledata Manchester - Delta House is an operational data center operated by Teledata UK in Manchester, United Kingdom. Our footprint estimate of its power is about 3.4 MW.

Key facts

StatusOperational
OperatorTeledata UK
Facility power3.4 MW (range 1.7 MW to 5.5 MW)
Estimate from building footprint, low confidence. Footprint estimate: about 2,848 m² building outline x 1 floor(s) x 1.2 kW/m².
GPU capacity if all AIabout 1,500 GPUs
If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count.
Networks34 networks, 1 internet exchanges
PeeringDB.
Also known asDatum Datacentres (MCR2) · Delta House
AddressDelta House, Wavell Road
Coordinates53.37912, -2.25854
Websiteteledata.co.uk

Power and grid

Nearest high-voltage substationMoss Nook, 132 kV, 2.3 km away
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationSouth Manchester Substation, 275 kV, 4.8 km away
HV substations within 10 km10
Power plants within 50 km3.3 GW in 82 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity218 g CO₂ per kWh (United Kingdom, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 31.3%, wind 29.4%, bioenergy 13.9%, nuclear 12.4%, solar 6.6%. Clean power: 64.2%

Climate and water

Average temperature9.1 °C
NASA POWER, average of 2001 to 2025.
Highest temperature28 °C (2001 to 2025)
Cooling degree days7 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy2.75 kWh per m² per day
Wind at 50 m7.2 m/s average
Water stress todayLow - Medium (10-20%) (England)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How much power does Teledata Manchester - Delta House use?

We estimate the facility power at about 3.4 MW. Estimate from building footprint, low confidence.

How close is Teledata Manchester - Delta House to the power grid?

The nearest high-voltage substation in OpenStreetMap is Moss Nook (132 kV), about 2.3 km away.

How clean is the power for Teledata Manchester - Delta House?

The grid in United Kingdom emits about 218 g CO₂ per kWh (2025). Largest sources: gas 31.3%, wind 29.4%, bioenergy 13.9%.

Who operates Teledata Manchester - Delta House?

Teledata UK.