Cincinnatti Bell - West 7th Street
Cincinnatti Bell - West 7th Street is an operational data center operated by Cincinnatti Bell in Cincinnati, United States. Our footprint estimate of its power is about 20 MW.
Key facts
| Status | Operational |
|---|---|
| Operator | Cincinnatti Bell |
| Facility power | 20 MW (range 10 MW to 32 MW) Estimate from building footprint, low confidence. Footprint estimate: about 2,820 m² building outline x 6 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 8,500 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Networks | 8 networks, 1 internet exchanges PeeringDB. |
| Also known as | CyrusOne Cincinnati 7th St · CyrusOne CIN2 |
| Address | 209 West 7 Street |
| Coordinates | 39.10279, -84.51726 |
| Website | cincinnatibell.com |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 3.2 km away Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Unnamed substation, 345 kV, 11.2 km away |
| HV substations within 10 km | 7 |
| Utility | Duke Energy Ohio INC (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | PJM |
| Nearest gas pipeline | Union Light Heat & Power, interstate pipeline, 2.4 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 5.4 GW in 22 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 536 g CO₂ per kWh (Ohio, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 54.9%, coal 24.4%, nuclear 11.7%, solar 5.8%, wind 2%. Clean power: 20% |
| Industrial power price | USD 0.098 per kWh (Ohio, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 41 °C (2001 to 2025) |
| Cooling degree days | 674 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 3.99 kWh per m² per day |
| Wind at 50 m | 4.6 m/s average |
| Water stress today | Low - Medium (10-20%) (Ohio) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Cincinnatti Bell - West 7th Street use?
We estimate the facility power at about 20 MW. Estimate from building footprint, low confidence.
How close is Cincinnatti Bell - West 7th Street to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 3.2 km away. The local utility is Duke Energy Ohio INC, in the PJM balancing area.
How clean is the power for Cincinnatti Bell - West 7th Street?
The grid in Ohio emits about 536 g CO₂ per kWh (2025). Largest sources: gas 54.9%, coal 24.4%, nuclear 11.7%.
Who operates Cincinnatti Bell - West 7th Street?
Cincinnatti Bell.
Data centers near Cincinnati
- DartPoints Cincinnati, OH - CVG1 508 m
- H5 Data Centers Cincinnati 799 m
- Level(3) Cincinnati 1.2 km
- T5@Cincinnati 1.7 km
- Encore Technologies NOR1 8.7 km
- CyrusOne Florence 16.2 km · 9.1 MW
- Data center in Sharonville 23.1 km · 4.2 MW
- Encore Technologies BLU1 23.2 km