Cogent New York 1

Cogent New York 1 is an operational data center operated by Cogent Communications in New York, United States. No power figure is public for this site yet.

Key facts

StatusOperational
OperatorCogent Communications
Networks7 networks
PeeringDB.
Address25 Broadway
Coordinates40.70578, -74.01397
Websitecogentco.com

Power and grid

Nearest high-voltage substationUnnamed substation, 138 kV, 900 m away (Consolidated Edison)
Straight-line distance. OpenStreetMap, substations of 100 kV and more.
Nearest 220 kV+ substationFarragut Substation, 345 kV, 2.5 km away
HV substations within 10 km39
UtilityConsolidated Edison Co-Ny INC (investor owned)
Electric retail service territory (HIFLD, US government).
Balancing authorityNYIS
Nearest gas pipelineBrooklyn Union Gas Co, intrastate pipeline, 2.9 km away
US Energy Information Administration pipeline map. Straight-line distance.
Power plants within 50 km19 GW in 137 plants
Plants with a stated output in OpenStreetMap. The largest four are listed.
Grid carbon intensity268 g CO₂ per kWh (New York, 2025)
Average of all power made in the area. Ember.
Grid power mixgas 45.4%, nuclear 20.7%, hydro 18.5%, solar 7.6%, wind 5%. Clean power: 52.9%
Industrial power priceUSD 0.105 per kWh (New York, August 2026)
Average price paid by industrial users in the state. EIA Electric Power Monthly.

Climate and water

Average temperature12.3 °C
NASA POWER, average of 2001 to 2025.
Highest temperature34.3 °C (2001 to 2025)
Cooling degree days481 per year (base 18.3 °C)
More cooling degree days means more energy for cooling.
Solar energy4.01 kWh per m² per day
Wind at 50 m6.9 m/s average
Water stress todayLow - Medium (10-20%) (New York)
Share of the local water supply that people already use. WRI Aqueduct 4.0, province level.
Water stress in 2050Low - Medium (10-20%)
Business-as-usual scenario.

Satellite view

Questions

How close is Cogent New York 1 to the power grid?

The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 900 m away. The local utility is Consolidated Edison Co-Ny INC, in the NYIS balancing area.

How clean is the power for Cogent New York 1?

The grid in New York emits about 268 g CO₂ per kWh (2025). Largest sources: gas 45.4%, nuclear 20.7%, hydro 18.5%.

Who operates Cogent New York 1?

Cogent Communications.