375 Pearl, Intergate.Manhattan
375 Pearl, Intergate.Manhattan is an operational data center operated by Sabey Data Centers in New York, United States. No power figure is public for this site yet.
Key facts
| Status | Operational |
|---|---|
| Operator | Sabey Data Centers |
| Networks | 9 networks, 1 internet exchanges PeeringDB. |
| Address | 375 Pearl |
| Coordinates | 40.71096, -74.00142 |
| Website | sabeydatacenters.com/intergate_manhattan |
Power and grid
| Nearest high-voltage substation | Unnamed substation, 138 kV, 1 km away (Consolidated Edison) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Farragut Substation, 345 kV, 1.6 km away |
| HV substations within 10 km | 35 |
| Utility | Consolidated Edison Co-Ny INC (investor owned) Electric retail service territory (HIFLD, US government). |
| Balancing authority | NYIS |
| Nearest gas pipeline | Brooklyn Union Gas Co, intrastate pipeline, 3 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Power plants within 50 km | 19 GW in 135 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 268 g CO₂ per kWh (New York, 2025) Average of all power made in the area. Ember. |
| Grid power mix | gas 45.4%, nuclear 20.7%, hydro 18.5%, solar 7.6%, wind 5%. Clean power: 52.9% |
| Industrial power price | USD 0.105 per kWh (New York, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 12.3 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 34.3 °C (2001 to 2025) |
| Cooling degree days | 481 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.01 kWh per m² per day |
| Wind at 50 m | 6.9 m/s average |
| Water stress today | Low - Medium (10-20%) (New York) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How close is 375 Pearl, Intergate.Manhattan to the power grid?
The nearest high-voltage substation in OpenStreetMap is an unnamed substation (138 kV), about 1 km away. The local utility is Consolidated Edison Co-Ny INC, in the NYIS balancing area.
How clean is the power for 375 Pearl, Intergate.Manhattan?
The grid in New York emits about 268 g CO₂ per kWh (2025). Largest sources: gas 45.4%, nuclear 20.7%, hydro 18.5%.
Who operates 375 Pearl, Intergate.Manhattan?
Sabey Data Centers.
Data centers near New York
- NYI NY1 (100 William Street) 565 m
- 33 Thomas Street 725 m · 4.9 MW
- Digital Realty NYC (60 Hudson) 950 m
- 365 Data Centers New York (NY10) 1.0 km
- Digital Realty NYC (32 AofA) 1.0 km · 6.1 MW
- 75 Broad Street 1.1 km
- Cogent New York 1 1.2 km
- Looking Glass Networks NYC Node 1.7 km
More Sabey Data Centers data centers
- Intergate.Quincy United States
- Intergate Columbia United States
- Sabey Intergate.Ashburn United States
- Intergate Seattle East Building 3 United States
- Data Center Germany
- Intergate Columbia B United States
- Intergate West / Digital.forest / Fortress United States
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.