Data center in Cheyenne
Data center in Cheyenne is an operational data center in Cheyenne, United States. Our footprint estimate of its power is about 22 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 22 MW (range 11 MW to 35 MW) Estimate from building footprint, low confidence. Footprint estimate: about 18,082 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 9,400 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 41.06313, -104.78020 |
Power and grid
| Utility | Cheyenne Light Fuel & Power (investor owned) Electric retail service territory (HIFLD, US government). |
|---|---|
| Balancing authority | WACM |
| Nearest gas pipeline | Southern Star Central Gas PL Co, interstate pipeline, 12.2 km away US Energy Information Administration pipeline map. Straight-line distance. |
| Grid carbon intensity | 145 g CO₂ per kWh (South Dakota, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 58%, hydro 22.3%, coal 9.3%, gas 8.5%, solar 2%. Clean power: 82.3% |
| Industrial power price | USD 0.094 per kWh (South Dakota, August 2026) Average price paid by industrial users in the state. EIA Electric Power Monthly. |
Climate and water
| Average temperature | 8.2 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 37.4 °C (2001 to 2025) |
| Cooling degree days | 304 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 4.57 kWh per m² per day |
| Wind at 50 m | 7.1 m/s average |
| Water stress today | Low - Medium (10-20%) (South Dakota) Share of the local water supply that people already use. WRI Aqueduct 4.0, province level. |
| Water stress in 2050 | Low - Medium (10-20%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Cheyenne use?
We estimate the facility power at about 22 MW. Estimate from building footprint, low confidence.
How clean is the power for Data center in Cheyenne?
The grid in South Dakota emits about 145 g CO₂ per kWh (2025). Largest sources: wind 58%, hydro 22.3%, coal 9.3%.
Data centers near Cheyenne
- Microsoft Bison Business Park Data Center 434 m · 94 MW
- Project Jade Data Center 3.4 km · 234 MW
- Data center in Cheyenne 3.9 km · 30 MW
- Data center in Cheyenne 4.2 km · 25 MW
- Meta Cheyenne Data Center 4.4 km · 215 MW
- Cogent Cheyenne 7.7 km
- Lunavi - Cheyenne 8.1 km
- Meta Cheyenne 9.2 km · 182 MW