Data center in Falkenstein
Data center in Falkenstein is an operational data center in Falkenstein, Germany. Our footprint estimate of its power is about 19 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 19 MW (range 9.4 MW to 30 MW) Estimate from building footprint, low confidence. Footprint estimate: about 15,597 m² building outline x 1 floor(s) x 1.2 kW/m². |
| GPU capacity if all AI | about 8,100 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 50.47674, 12.33346 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Falkenstein, 110 kV, 500 m away (Mitnetz Strom) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Herlasgrün, 220 kV, 12 km away |
| HV substations within 10 km | 3 |
| Power plants within 50 km | 2.2 GW in 35 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 7.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.9 °C (2001 to 2025) |
| Cooling degree days | 85 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Falkenstein use?
We estimate the facility power at about 19 MW. Estimate from building footprint, low confidence.
How close is Data center in Falkenstein to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Falkenstein (110 kV), about 500 m away.
How clean is the power for Data center in Falkenstein?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Data centers near Falkenstein
- Data center in Falkenstein 203 m · 9 MW
- Hetzner Online FSN1 (Falkenstein) 248 m · 26 MW
- Data center in Falkenstein 337 m · 8.2 MW
- noris network datacenter.de HOF1 35.6 km
- nbiserv 51.2 km
- Carrierswitchraum Jena 70.4 km
- Intershop-Tower Jena 72.8 km
- Universitätsrechenzentrum 73.2 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.