Data center in Falkenstein
Data center in Falkenstein is an operational data center in Falkenstein, Germany. Our footprint estimate of its power is about 9 MW.
Key facts
| Status | Operational |
|---|---|
| Facility power | 9 MW (range 3.6 MW to 23 MW) Estimate from building footprint, low confidence. Footprint estimate: about 75,058 m² site outline x 0.12 kW per m² of land. |
| GPU capacity if all AI | about 3,800 GPUs If all IT power ran GB200-class GPUs at 1.8 kW each, all-in (PUE 1.3). An upper bound, not a count. |
| Coordinates | 50.47842, 12.33236 |
Power and grid
| Nearest high-voltage substation | Umspannwerk Falkenstein, 110 kV, 400 m away (Mitnetz Strom) Straight-line distance. OpenStreetMap, substations of 100 kV and more. |
|---|---|
| Nearest 220 kV+ substation | Umspannwerk Herlasgrün, 220 kV, 11.8 km away |
| HV substations within 10 km | 3 |
| Power plants within 50 km | 2.2 GW in 35 plants
Plants with a stated output in OpenStreetMap. The largest four are listed. |
| Grid carbon intensity | 334 g CO₂ per kWh (Germany, 2025) Average of all power made in the area. Ember. |
| Grid power mix | wind 26.6%, coal 21%, solar 18%, gas 16.8%, bioenergy 10.1%. Clean power: 58.5% |
| Industrial power price | EUR 0.146 per kWh (Germany, 2026-S1) Non-household users with 20 to 70 GWh per year, without VAT. Eurostat. |
Climate and water
| Average temperature | 7.6 °C NASA POWER, average of 2001 to 2025. |
|---|---|
| Highest temperature | 35.9 °C (2001 to 2025) |
| Cooling degree days | 85 per year (base 18.3 °C) More cooling degree days means more energy for cooling. |
| Solar energy | 2.96 kWh per m² per day |
| Wind at 50 m | 5.6 m/s average |
| Water stress today | Medium - High (20-40%) (Germany) Share of the local water supply that people already use. WRI Aqueduct 4.0, country level. |
| Water stress in 2050 | Medium - High (20-40%) Business-as-usual scenario. |
Satellite view
Google satellite · Copernicus Sentinel-2 history · OpenStreetMap
Questions
How much power does Data center in Falkenstein use?
We estimate the facility power at about 9 MW. Estimate from building footprint, low confidence.
How close is Data center in Falkenstein to the power grid?
The nearest high-voltage substation in OpenStreetMap is Umspannwerk Falkenstein (110 kV), about 400 m away.
How clean is the power for Data center in Falkenstein?
The grid in Germany emits about 334 g CO₂ per kWh (2025). Largest sources: wind 26.6%, coal 21%, solar 18%.
Data centers near Falkenstein
- Hetzner Online FSN1 (Falkenstein) 181 m · 26 MW
- Data center in Falkenstein 203 m · 19 MW
- Data center in Falkenstein 351 m · 8.2 MW
- noris network datacenter.de HOF1 35.7 km
- nbiserv 51.0 km
- Carrierswitchraum Jena 70.2 km
- Intershop-Tower Jena 72.7 km
- Universitätsrechenzentrum 73.1 km
Sources
Correct this page or get the data
Do you know this site? Send a correction, a power figure or a chip count. Do you need the full dataset, power demand by region, or a list of sites that need power? Leave your email.